Objective: The present study aims to compare the correlation dimension and second-order entropy at the minimum embedding dimension with the correlation dimension (D) and second-order entropy (K) based on their efficiency and accuracy in differentiating between normal and pathologic voices.

Methods: The minimum embedding dimension was estimated with the Cao method. Nonlinear dynamic parameters, such as correlation dimension and second-order entropy, were used to quantitatively analyze the normal and pathologic voice samples.

Results: The computing time of the correlation dimension and second-order entropy at the minimum embedding dimension was reduced to approximately one third of that of traditional D and K calculations, reflecting higher efficiency. The statistical results of linear fitting suggested that the correlation dimension was highly correlated to the correlation dimension at the minimum embedding dimension, and second-order entropy calculation was highly correlated to the second-order entropy at the minimum embedding dimension. Lastly, the results of statistical comparison proved that the correlation dimension at the minimum embedding dimension and second-order entropy at the minimum embedding dimension were able to significantly differentiate between normal and disordered voices (P <0.001).

Conclusions: The results suggest that the correlation dimension and second-order entropy at the minimum embedding dimension are valid analysis tools for the diagnosis of voice disorders. Additionally, the efficiency and accuracy of these parameters yield potential for clinical usage because of lower computation time than current methods.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jvoice.2016.07.021DOI Listing

Publication Analysis

Top Keywords

minimum embedding
32
embedding dimension
32
correlation dimension
28
second-order entropy
28
dimension second-order
24
entropy minimum
16
dimension
15
nonlinear dynamic
8
minimum
8
embedding
8

Similar Publications

Removal of an incarcerated intrauterine device reaching the serosal surface of the uterus by hysteroscopy alone: a case report.

Front Med (Lausanne)

January 2025

Department of Gynecology and Obstetrics, International Peace Maternity and Child Health Hospital Shanghai Jiao Tong University School of Medicine, Shanghai Key Laboratory of Embryo Original Diseases, Shanghai Municipal Key Clinical Specialty, Shanghai, China.

Background: An intrauterine device (IUD) is a widely used long-term contraceptive device for family planning. However, the IUD can lead to various complications. Severe complications and remedial measures caused by IUDs have been reported in the literature; however, detailed surgical approaches for safely removing the IUD within the minimum surgical range have rarely been described especially in postmenopausal women.

View Article and Find Full Text PDF

Nowadays, gastroesophageal reflux disease (GERD) has emerged as one of the major hazards to the health of the upper gastrointestinal tract, and there is an urgent need for a low-cost, user-friendly, and non-invasive detection method. Herein, a paper-based sensor (CP sensor) for the non-invasive screening of GERD is proposed. The sensor is structured as a specially shaped cellulose paper strip embedded with fluorescent colloids, which are self-assembled from a cleavable synthetic fluorescent polymer (P4).

View Article and Find Full Text PDF

Selecting Initial Conditions for Trajectory-Based Nonadiabatic Simulations.

Acc Chem Res

January 2025

Centre for Computational Chemistry, School of Chemistry, University of Bristol, Bristol BS8 1TS, United Kingdom.

ConspectusPhotochemical reactions have always been the source of a great deal of mystery. While classified as a type of chemical reaction, no doubts are allowed that the general tenets of ground-state chemistry do not directly apply to photochemical reactions. For a typical chemical reaction, understanding the critical points of the ground-state potential (free) energy surface and embedding them in a thermodynamics framework is often enough to infer reaction yields or characteristic time scales.

View Article and Find Full Text PDF

Objective: The objective of this study was to investigate the utility of preoperative 18F-FDG PET/CT scanning in preoperative evaluation and surgical planning for pulmonary tuberculosis.

Methods: The study involved a retrospective analysis of clinical data and preoperative chest 18F-FDG PET/CT data of 24 patients with pulmonary tuberculosis who underwent pneumonectomy at the Shanghai Public Health Clinical Center between December 2017 and January 2022.

Results: All 24 patients successfully underwent chest 18F-FDG PET/CT imaging, and complete data pertaining to the maximum standardized uptake value, mean standardized uptake value, minimum standardized uptake value, total lesion glycolysis, and metabolic tumor volume were obtained.

View Article and Find Full Text PDF

Physicochemical Properties, Antioxidant Capacity and Bioavailability of Whey Protein Concentrate-Based Coenzyme Q10 Nanoparticles.

Antioxidants (Basel)

December 2024

Department of Nutrition and Food Sciences, College of Agriculture and Life Sciences, University of Vermont, Burlington, VT 05405, USA.

Coenzyme Q10 (CoQ10) is a powerful antioxidant. However, the poor water solubility and low bioavailability still remain challenges for its application. An embedded delivery system of CoQ10 based on whey protein concentrate (WPC) and polymerized whey protein concentrate (PWPC) was prepared, and the physicochemical properties, antioxidant capacity and bioavailability were characterized in this study.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!