The T-SCAN System in Evaluating Occlusal Contacts.

Folia Med (Plovdiv)

Department of Prosthetics, Faculty of Dental Medicine, Medical University of Plovdiv, Plovdiv, Bulgaria

Published: January 2017

Background: Normal occlusal and articulation relations between the jaws ensure equal distribution of occlusal forces during mastication. A T-SCAN system allows these relations to be measured dynamically during the articulation cycle.

Aim: To evaluate the T-SCAN III system in measuring and assessing the forces of occlusal contacts and their digital presentation.

Patients And Methods: Thirty students aged 19 - 22 years were examined. Of these only one matched the study criteria: - intact dentition; - without or with class I fillings in teeth 36 or 46; - Angle's class I jaw relation We used a computerized occlusal analysis system T-SCAN in the study. It comes with a registering sensor for the occlusal contacts, a module for transmitting the signals to a computer, and conversion software to generate images on a computer screen.

Results: We evaluated the system's capabilities in registering the occlusal contacts during mastication on an occlusion film and the occlusal forces using a digital display.

Conclusion: The T-SCAN system provides the only accurate way to determine and evaluate the time sequence and force of occlusal contacts by converting the qualitative data into quantitative and displaying them digitally.

Download full-text PDF

Source
http://dx.doi.org/10.1515/folmed-2016-0015DOI Listing

Publication Analysis

Top Keywords

occlusal contacts
20
t-scan system
12
occlusal
9
occlusal forces
8
t-scan
5
contacts
5
system evaluating
4
evaluating occlusal
4
contacts background
4
background normal
4

Similar Publications

Aim: Aberrative occlusal contacts were associated with Temporomandibular disorder (TMD), but whether stabilization splints with therapeutic exercises alleviate the symptoms is unclear. Hence, this study aims to compare the short-term efficacy of occlusal splint therapy and the synergistic effect of therapeutic exercise with occlusal splint therapy for 3 weeks in individuals with TMD.

Settings And Design: in-vivo observational pilot study.

View Article and Find Full Text PDF

Occlusion plays a crucial role in the long-term success and functionality of dental restorations. The purpose of this study was to investigate the changes in occlusal contacts upon the cementation of zirconia crowns with different cement spacer settings in computer-aided design and computer-aided manufacturing (CAD-CAM) software (3Shape Dental System version 2.102.

View Article and Find Full Text PDF

Automatic adjustment of dental crowns using Laplacian mesh editing.

J Mech Behav Biomed Mater

December 2024

Department of Prosthetic Dentistry and Biomedical Materials Science, Hannover Medical School, Carl-Neuberg-Str. 1, 30625, Hannover, Germany. Electronic address:

Currently, the restoration of missing teeth by means of dental implants is a common treatment method in dentistry. Ensuring optimal contact between teeth (occlusion) when designing the occlusal surface of an implant-supported crown is crucial for the patient. Although there are various occlusal concepts and guidelines for achieving optimised occlusion, adapting an occlusal surface is challenging.

View Article and Find Full Text PDF

This study was carried out to compare the stability of Le Fort I maxillary advancement between the surgery-first approach (SFA) and the orthodontics-first approach (OFA), and to evaluate the impact of the quality of postoperative occlusion on maxillary stability. In total, 26 patients (13 SFA and 13 OFA) were included in this study. Cone beam computed tomography (CBCT) scans taken at T0 (1 week before surgery), T1 (1 week after surgery), and T2 (6 months after surgery) were used for the assessment of maxillary stability.

View Article and Find Full Text PDF

Statement Of Problem: The accuracy of the interproximal and occlusal contacts of single posterior implant-supported restorations designed using computer-aided design (CAD) software programs remains uncertain.

Purpose: The aim of this clinical study was to assess the interproximal and occlusal contacts of single posterior implant-supported restorations designed with 2 distinct dental CAD software programs.

Material And Methods: Forty single posterior implant-supported restorations were evaluated for interproximal and occlusal contacts.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!