Elective or Emergency Use of Mechanical Circulatory Support Devices During Transcatheter Aortic Valve Replacement.

J Interv Cardiol

Cardiovascular Division, University of Miami Miller School of Medicine, and the Elaine and Sydney Sussman Cardiac Catheterization Laboratory, University of Miami Hospital, Miami, Florida.

Published: October 2016

Objective: Evaluate the use of mechanical circulatory support (MCS) devices in high-risk patients undergoing transcatheter aortic valve replacement (TAVR).

Background: The use of MCS devices in elderly patients with multiple comorbidities undergoing TAVR is underexplored.

Methods: All patients undergoing TAVR at a single tertiary academic center who required MCS during index procedure between 2008 and 2015 were included in a prospective database.

Results: MCS was used in 9.4% (54/577) of all TAVRs (n = 52 Edwards Sapien and n = 2 CoreValves) of which 68.5% (n = 37) were used as part of a planned strategy, and 31.5% (n = 17) were used in emergency "bail-out" situations. IABP was the most commonly used device (87%) followed by Impella and ECMO (6% each). Among the MCS group, 22% required cardiopulmonary resuscitation during the procedure (n = 4 elective [11%] vs. n = 8 emergent [47%]) and 15% upgrade to a second device (Impella or CPB after IABP; n = 5 elective [14%] vs. n = 3 emergent [18%]). Median duration of support was 1-day. Device related complications were low (4%). In-hospital mortality in this extremely high-risk population was 24% (13/54) (11% [4/37] for elective cases and 53% [9/17] for emergency cases). Cardiogenic shock (50%) was the most common cause of in-hospital death. Cumulative all-cause 1-year mortality was 35% (19/54) (19% 97/370 for elective and 71% [12/17] for emergency cases).

Conclusion: Emergent use of MCS during TAVR in extremely high-risk population is associated with high short and long-term mortality rates. Early identification of patients at risk for hemodynamic compromise may rationalize elective utilization of MCS during TAVR.

Download full-text PDF

Source
http://dx.doi.org/10.1111/joic.12323DOI Listing

Publication Analysis

Top Keywords

mechanical circulatory
8
circulatory support
8
transcatheter aortic
8
aortic valve
8
valve replacement
8
mcs devices
8
patients undergoing
8
undergoing tavr
8
extremely high-risk
8
high-risk population
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!