The pes of Australovenator wintonensis (Theropoda: Megaraptoridae): analysis of the pedal range of motion and biological restoration.

PeerJ

Palaeontology, Australian Age of Dinosaurs Museum of Natural History , Winton , Queensland , Australia.

Published: August 2016

The pedal range of motion in Australovenator wintonensis is investigated to determine what influence soft tissue had on range of motion in the foot. Fortunately, the theropod pes shares a close morphology with extant large cursorial birds. Therefore, to better understand the pedal range of motion of Australovenator, the pedal range of motion of Dromaius novaehollandiae (commonly known as the emu) was analysed with and without soft tissue. We used a variety of innovative digital techniques to analyse the range of motion and biologically restore the Australovenator pes. Computed tomography scans of Dromaius pes in fully flexed and fully extended positions provided the soft tissue range of motion limits. The bone on bone range of motion of the same specimen was replicated following the removal of soft tissue. It was identified that there was an increase in range of motion potential with the removal of soft tissue. This variation provided a guide to develop the potential range of motion of a fully fleshed Australovenator pes. Additionally, the dissection of the Dromaius pes provided a guide enabling the replication of the corresponding soft tissue and keratin sheaths of the Australovenator pes.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4975041PMC
http://dx.doi.org/10.7717/peerj.2312DOI Listing

Publication Analysis

Top Keywords

range motion
40
soft tissue
24
pedal range
16
australovenator pes
12
range
10
motion
10
australovenator wintonensis
8
motion australovenator
8
tissue range
8
dromaius pes
8

Similar Publications

WearMoCap: multimodal pose tracking for ubiquitous robot control using a smartwatch.

Front Robot AI

January 2025

Interactive Robotics Laboratory, School of Computing and Augmented Intelligence (SCAI), Arizona State University (ASU), Tempe, AZ, United States.

We present WearMoCap, an open-source library to track the human pose from smartwatch sensor data and leveraging pose predictions for ubiquitous robot control. WearMoCap operates in three modes: 1) a Watch Only mode, which uses a smartwatch only, 2) a novel Upper Arm mode, which utilizes the smartphone strapped onto the upper arm and 3) a Pocket mode, which determines body orientation from a smartphone in any pocket. We evaluate all modes on large-scale datasets consisting of recordings from up to 8 human subjects using a range of consumer-grade devices.

View Article and Find Full Text PDF

Background: Stereotactic body radiation therapy (SBRT) is crucial for treating early-stage inoperable non-small cell lung cancer (NSCLC) due to its precision and high-dose delivery. This study aimed to investigate the dosimetric deviations in gated (GR) versus non-gated radiotherapy (NGR), analyzing the impact of tumor location, target volume, and tumor motion range on dose distribution accuracy.

Methods: Sixty patients treated with either gated (n=30) or non-gated (n=30) SBRT for early-stage NSCLC were retrospectively analyzed.

View Article and Find Full Text PDF

This study aimed to verify the correlations between variables obtained from dry-land tests and swimming performance, in addition to examining the associations between the dry-land asymmetries and swimming performance. Thirty-seven male swimmers performed a test battery, including shoulder isokinetic torque, shoulder range of motion (ROM), vertical jump, anthropometric, and in-water force tests. Additionally, the best official performance in the events of 50 and 200 m front crawl was obtained.

View Article and Find Full Text PDF

This study aimed to (1) examine the acute changes in the glenohumeral range of motion (ROM) after repetitive pitching and (2) clarify whether arm speed during pitching is associated with changes in the glenohumeral internal rotation (IR) and horizontal adduction (HADd) ROM. Fifteen healthy college males with over five years of baseball experience participated. Glenohumeral ROMs of IR, external rotation, and HADd were measured using a digital inclinometer before, immediately after, and one day after completing 100 repetitive full-effort pitches.

View Article and Find Full Text PDF

The effect of cervical spine flexion-extension motion on odontoid parameters.

J Orthop Surg Res

January 2025

Department of Spine Surgery, The First Affiliated Hospital of Guangxi Medical University, 6 Shuangyong Road, Guangxi Zhuang Autonomous Region, Nanning, 530021, China.

Objective: To assess the stability of odontoid parameters on flexion-extension motion and to validate the accuracy of the physiological cervical lordosis (CL) predictive formula across different cervical positions.

Methods: Standard cervical spine lateral radiographs in neutral, flexion, and extension positions were collected to measure odontoid incidence (OI), odontoid tilt (OT), C2 slope (C2S), CL, T1 slope (T1S), and T1S minus CL (T1S-CL). Friedman's test was used to assess the differences in parameters among the three cervical spine positions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!