Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Lesion length has been an important factor in predicting a worse outcome after percutaneous coronary interventions (PCI); however, the safety and efficacy of second-generation drug eluting stents in very long coronary lesions has not been validated in large scale randomized controlled trials.
Methods: We performed a patient level pooled analysis of 13,266 patients undergoing planned overlapping stent treatment of very long coronary lesions with the XIENCE V everolimus eluting coronary stent system from 6 trials evaluating the XIENCE V stent (Spirit II, III, IV, V, Spirit Small Vessel and XIENCE V USA). Patients were divided into two cohorts, a very long lesion (VLL) group (lesions ≥35 mm) and a control group (lesions >24 to <35 mm). The primary outcome measures were Target Lesion Failure (TLF), Major Adverse Cardiac Events (MACE), and Academic Research Consortium (ARC) defined definite and probable stent thrombosis at 1 year.
Results: A total of 13,266 patients were included in the pooled analysis of which 2.4% (323 patients with 328 total lesions) had a mean lesion length of 47.1 ± 13.7 mm in the VLL group which were compared to controls comprised of 3.6% of the cohort (482 patients with 500 total lesions) with mean lesion length of 28.1 ± 2.4 mm.There was no significant difference in the rates of TLF between the VVL and control groups (8.9 vs. 10%, P = 0.63), MACE (9.2 vs. 10%, P = 0.74) or stent thrombosis (1.6 vs. 1.5%, P = 0.92) at 1 year.
Conclusions: In the treatment of very long coronary lesions, the XIENCE V stent appears as safe and effective as percutaneous coronary interventions for long lesions. © 2016 Wiley Periodicals, Inc.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/ccd.26711 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!