Background: The methods to standardize the test items used for classification of patients with knee pain based on the movement system impairment (MSI) approach have been established. To our knowledge, no study has concentrated on establishing reliability for proposed classification for knee pain problems.

Objective: The aim of the study was to assess intra- and intertester reliability of the knee MSI classification in patients with knee pain.

Design: A cross-sectional methodological study.

Setting: Rasul Akram Hospital.

Participants: Ninety-six subjects with knee pain aged 18-65 years.

Methods: In order to examine intertester reliability, all three testers assessed the symptoms, signs and the MSI diagnosis of subjects with knee pain simultaneously. In order to assess intratester reliability, the procedure was exactly repeated after a one-week intersession period. Kappa values and percentages of agreement were calculated to analyze the reliability level.

Results: The kappa values for intra- and intertester reliability of the symptom items ranged from 0.83 to 1.00 and 0.00 to 0.83, respectively. For the sign items, the kappa values ranged from 0.18 to 1.00 and 0.00 to 0.82, respectively. Finally, the kappa values of intra- and intertester reliability for patients' classification judgments ranged from 0.66 to 0.71, and 0.48 to 0.58, respectively.

Conclusion: The results of the present study indicate that intertester reliability for the symptoms, signs and classification judgments of patients with knee pain based on the MSI approach seemed generally acceptable. However, for intratester reliability, lower levels of the system were observed, probably due to different pain levels or pain behavior between test and retest sessions.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.math.2016.07.014DOI Listing

Publication Analysis

Top Keywords

intertester reliability
24
knee pain
24
patients knee
16
kappa values
16
classification patients
12
intra- intertester
12
reliability
10
movement system
8
knee
8
pain
8

Similar Publications

The PULSE workload monitor (PULSE) is a commercially available, wearable device that assesses upper extremity kinematics and kinetics during overhand pitching with three metrics to improve pitching performance. The purpose of this study was to determine the inter-tester and intra-tester reliability of the PULSE metrics when applied by a lay consumer versus trained researcher. A total of 14 healthy, adult male (age: 44.

View Article and Find Full Text PDF

Intra and Inter-Test Reliability of Isometric Hip Adduction Strength Test with Force Plates in Professional Soccer Players.

J Funct Morphol Kinesiol

December 2024

Escuela de Ciencias de la Actividad Física, El Deporte y la Salud, Facultad de Ciencias Médicas, Universidad de Santiago de Chile, Santiago 8370003, Chile.

Assessing the reliability of measurement instruments and equipment is essential to ensure the accurate tracking of athletes over extended periods, minimizing the measurement errors caused by chance or other factors. However, a less common but equally important analysis is the verification of inter-measurement agreement, which complements the reliability results. To evaluate the intra- and inter-test reliability of an isometric hip adduction strength and asymmetries test in professional soccer players.

View Article and Find Full Text PDF

Background: Literature assessing elasticity in rotator cuff (RC) muscles with shear wave elastography (SWE) is growing but little is known about the overall measurement properties. However, this information is crucial before implementation in research or practice. The objective of this review was first, to systematically investigate the evidence regarding reliability and validity of rotator cuff (RC) muscles shear wave elastography (SWE).

View Article and Find Full Text PDF

Purpose: To evaluate long-term retention, compliance, and performance of glaucoma patients using a virtual reality portable perimeter to monitor visual fields (VFs) at home.

Design: Prospective, longitudinal, cohort study.

Subjects: Twenty-five glaucoma patients with stable and reliable VFs (average age 67.

View Article and Find Full Text PDF

Ultrasound evaluation of deep fascia thickness: Reliability and association with clinically evaluated changes.

J Bodyw Mov Ther

October 2024

Department of Physical Therapy, Recanati School for Community Health Professions, Faculty of Health Sciences at Ben-Gurion University of the Negev, Beer-Sheva, Israel. Electronic address:

Background: There is growing evidence of fascial involvement in musculoskeletal pathologies; thus, measuring the fascia's properties is clinically essential.

Objectives: 1) to evaluate intra- and inter-tester reliability of sonographic measurements of deep fascia thickness in healthy individuals; 2) to assess whether fascial thickness in areas of fascial movement restriction (fascial densification in Stecco's Fascial Manipulation method), differs from contralateral areas with normal fascia.

Methods: Part 1 (reliability study): Fascial thickness was sonographically measured in 10 sites (5 on each side), twice by a single examiner to assess intra-rater reliability and once by a second examiner to evaluate inter-rater reliability.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!