Purpose: A low concentration of macular carotenoid pigment (lutein and zeaxanthin) is a significant risk factor for macular degeneration. The goal of this paper is to investigate the relationship between macular pigment optical density (MPOD) and lacquer cracks (LC) in high myopia.
Methods: This is a prospective comparative observational study (NCT02205632) including high myopic patients with or without LC. High myopia was defined as a refractive error greater than 6 diopters of myopia or axial length greater than 26mm. All patients underwent best-corrected visual acuity in logMAR, MPOD measurement, multicolor imaging, SD-OCT, autofluorescence and axial length measurement. MPOD was calculated using heterochromatic flicker photometry. Group 1 was defined as eyes without LC and group 2 as eyes with LC.
Results: Forty-five eyes of 32 patients with a mean age of 51.3 years were included in group 1, and 15 eyes of 13 patients aged 54.1 in group 2 (P=0.56). Mean spherical equivalent was -10.11 diopters in group 1 and -15.11 in group 2 (P=0.0004). Mean visual acuity was +0.08 logMAR (0.8 in decimal notation) in group 1 and +0.11 logMAR (0.8 in decimal notation) in group 2 (P=0.061). Axial length was 27.8mm in group 1 and 29.2 in group 2 (P=0.0052). Central macular thickness was lower in group 1 (295μm) than in group 2 (305μm) (P<0.0001), and macular choroidal thickness did not differ between the two groups (P=0.094). Mean MPOD in group 2 was 0.52 and 0.63 in group 1 (P=0.042). Differences in axial length were not related to MPOD measurements (P=0.74).
Conclusion: A lower rate of MPOD was observed in cases of LC in high myopia. Further studies are needed to investigate if dietary carotenoids could have a protective effect in reducing the risk of LC.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jfo.2016.04.001 | DOI Listing |
In Vitro Model
December 2024
Laboratório de Biologia Básica de Células-Tronco, FIOCRUZ, Rua Professor Algacyr Munhoz Mader, 3775, Instituto Carlos Chagas, Curitiba, Paraná PR 81350-010 Brazil.
Obesity is associated with several comorbidities that cause high mortality rates worldwide. Thus, the study of adipose tissue (AT) has become a target of high interest because of its crucial contribution to many metabolic diseases and metabolizing potential. However, many AT-related physiological, pathophysiological, and toxicological mechanisms in humans are still poorly understood, mainly due to the use of non-human animal models.
View Article and Find Full Text PDFNat Commun
January 2025
Department of Biomedical Engineering, State University of New York at Binghamton, Binghamton, NY, 13902, USA.
Creating durable, motion-compliant neural interfaces is crucial for accessing dynamic tissues under in vivo conditions and linking neural activity with behaviors. Utilizing the self-alignment of nano-fillers in a polymeric matrix under repetitive tension, here, we introduce conductive carbon nanotubes with high aspect ratios into semi-crystalline polyvinyl alcohol hydrogels, and create electrically anisotropic percolation pathways through cyclic stretching. The resulting anisotropic hydrogel fibers (diameter of 187 ± 13 µm) exhibit fatigue resistance (up to 20,000 cycles at 20% strain) with a stretchability of 64.
View Article and Find Full Text PDFKlin Monbl Augenheilkd
January 2025
Medical Faculty, University of Basel, Switzerland.
Background: The global incidence of high myopia is increasing, with projections indicating a rise from 3 to 10% of the global population by 2050. Effective treatment options exist to reduce myopia progression, but their success is contingent on patient adherence. This study assesses the impact of changes in treating physicians on adherence to therapy to control myopia progression.
View Article and Find Full Text PDFJ Ophthalmol
January 2025
Optics and Optometry Department, Universidad Complutense de Madrid, Madrid, Spain.
To analyze the refractive accuracy of a novel swept-source optical coherence biometer (SS-OCT), that uses individual refractive indices to measure axial length, in short and long eyes implanted with monofocal intraocular lenses (IOLs). This retrospective comparative study considered eyes with short axial length (AL) (< 22.5 mm) or long AL (> 26 mm) bilaterally implanted with the Acrysof IQ monofocal IOL.
View Article and Find Full Text PDFJ Mol Model
January 2025
School of Mechanics and Safety Engineering, Zhengzhou University, Zhengzhou, 450001, People's Republic of China.
Context: SiGe nanotubes (SiGeNTs) hold significant promise for applications in nanosolar cells, optoelectronic systems, and interconnects, where thermal conductivity is critical to performance. This study investigates the effects of length, diameter, temperature, and axial strain on the thermal conductivity of armchair and zigzag SiGeNTs through molecular dynamics simulations. Results indicate that thermal conductivity increases with sample length due to ballistic heat transport and decreases with temperature as phonon scattering intensifies.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!