AI Article Synopsis

  • Chronic noise exposure can lead to Alzheimer's disease-like changes in the brain, such as increased tau hyperphosphorylation and β-amyloid buildup in the prefrontal cortex (PFC).
  • The study focused on how chronic noise affects the corticotropin-releasing factor (CRF) system, which plays a key role in stress response and tau regulation.
  • Results showed that chronic noise exposure elevated levels of corticosterone, CRF, and its receptor CRFR1, linking these changes to tau phosphorylation in PFC neurons, suggesting a potential mechanism in noise-induced cognitive decline.

Article Abstract

Chronic noise exposure has been associated with Alzheimer's disease (AD)-like pathological changes, such as tau hyperphosphorylation and β-amyloid peptide accumulation in the prefrontal cortex (PFC). Corticotropin-releasing factor (CRF) is the central driving force in the stress response and a regulator of tau phosphorylation via binding to CRF receptors (CRFR). Little is known about the CRF system in relation to noise-induced AD-like changes in the PFC. The aim of this study was to explore the effects of chronic noise exposure on the CRF system in the PFC of rats and its relationship to tau phosphorylation. Male Wistar rats were randomly divided into control and noise exposure groups. The CRF system was evaluated following chronic noise exposure (95dB sound pressure level white noise, 4h/day×30days). Chronic noise significantly accelerated the progressive overproduction of corticosterone and upregulated CRF and CRFR1 mRNA and protein, both of which persisted 7-14days after noise exposure. In contrast, CRFR2 was elevated 3-7days following the last stimulus. Double-labeling immunofluorescence co-localized p-tau with CRF in PFC neurons. The results suggest that chronic noise exposure elevates the expression of the CRF system, which may contribute to AD-like changes.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jns.2016.07.049DOI Listing

Publication Analysis

Top Keywords

chronic noise
24
noise exposure
24
crf system
16
noise
9
crf
9
effects chronic
8
mrna protein
8
expression crf
8
prefrontal cortex
8
tau phosphorylation
8

Similar Publications

Assessment of Emphysema on X-ray Equivalent Dose Photon-Counting Detector CT: Evaluation of Visual Scoring and Automated Quantification Algorithms.

Invest Radiol

October 2024

From the Institute for Diagnostic and Interventional Radiology, University Hospital Zurich, University Zurich, Zurich, Switzerland (B.K., F.E., J.K., T.F., L.J.); Advanced Radiology Center, Department of Diagnostic Imaging and Oncological Radiotherapy, Fondazione Policlinico Universitario "A. Gemelli" IRCCS, Rome, Italy (C.S., A.R.L.); and Section of Radiology, Department of Radiological and Hematological Sciences, Università Cattolica del Sacro Cuore, Rome, Italy (A.R.L.).

Objectives: The aim of this study was to evaluate the feasibility and efficacy of visual scoring, low-attenuation volume (LAV), and deep learning methods for estimating emphysema extent in x-ray dose photon-counting detector computed tomography (PCD-CT), aiming to explore future dose reduction potentials.

Methods: One hundred one prospectively enrolled patients underwent noncontrast low- and chest x-ray dose CT scans in the same study using PCD-CT. Overall image quality, sharpness, and noise, as well as visual emphysema pattern (no, trace, mild, moderate, confluent, and advanced destructive emphysema; as defined by the Fleischner Society), were independently assessed by 2 experienced radiologists for low- and x-ray dose images, followed by an expert consensus read.

View Article and Find Full Text PDF

: This study examines the potential associations between salivary cortisol concentrations and subjective stress test scores in healthy individuals subjected to sound-related, psychological, and physical stressors. : This study employed a single-center observational cross-sectional design, with a sample size of 36 subjects recruited from a tertiary referral audiology center. Between 2023 and 2024, the study recruited subjects with normal hearing, baseline salivary cortisol levels, and subjective stress levels.

View Article and Find Full Text PDF

To obtain broad regulatory approval for a new analgesic agent in acute postoperative pain, US and European regulatory authorities require pivotal studies in both hard (bony) tissue pain and soft tissue pain. Bunionectomy is by far the most common hard tissue pivotal trial model, in spite of the fact that the model has limited relevance to clinicians prescribing pain drugs (pain from bunionectomy is not extreme or long-lasting, and is adequately treated by existing drugs). The authors outline the experimental characteristics that make bunionectomy an appealing study model for researchers despite its lack of clinical relevance compared to larger surgeries.

View Article and Find Full Text PDF

Dysregulation of Long Non-coding RNAs-the Novel lnc in Metal Toxicity and Carcinogenesis.

Curr Environ Health Rep

December 2024

Stony Brook Cancer Center, Stony Brook University, Stony Brook, NY, 11794, USA.

Purpose Of Review: Metals are common environmental pollutants. Acute and chronic exposures to non-essential toxic metals or excessive essential metals cause various diseases including cancer in humans. However, the underlying mechanisms have not been well understood.

View Article and Find Full Text PDF

Robust thoracic CT image registration with environmental adaptability using dynamic Welsch's function and hierarchical structure-awareness strategy.

Quant Imaging Med Surg

December 2024

Anhui Province Key Laboratory of Medical Physics and Technology, Institute of Health and Medical Technology, Hefei Institutes of Physical Science, Hefei Cancer Hospital, Chinese Academy of Sciences, Hefei, China.

Background: Robust registration of thoracic computed tomography (CT) images is strongly impacted by motion during acquisition, high-density objects, and noise, particularly in lower-dose acquisitions. Despite the enhanced registration speed achieved by popular deep learning (DL) methods, their robustness is often neglected. This study aimed to develop a robust thoracic CT image registration algorithm to address the aforementioned issues.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!