A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Effect of Trypan Blue on Descemet Membrane Elasticity. | LitMetric

Effect of Trypan Blue on Descemet Membrane Elasticity.

Cornea

*Loyola University of Chicago, Maywood, IL; †Thomas John Vision Institute, Oak Lawn, IL; ‡Iladevi Cataract and IOL Research Centre, Ahmedabad, Gujarat, India; §Department of Chemical Sciences, Central University of Gujarat, Gandhinagar, Gujarat, India; ¶Ocular Surface Center, Miami, FL; and ‖Department of Ophthalmology, Florida International University, Herbert Wertheim College of Medicine, Miami, Florida.

Published: November 2016

Purpose: To evaluate the effect of trypan blue on the elastic property of Descemet membrane (DM) by atomic force microscopy.

Methods: Human corneas (n = 10) were obtained from the Illinois Eye Bank (Chicago, IL). The DM was isolated and divided into two halves, one half was stained with ophthalmic trypan blue (Vision Blue, 0.06%, DORC International), whereas the unstained other half served as control. The DM samples were then tested using the atomic force microscope. Data were analyzed using the Hertz model for the evaluation of the Young modulus of elasticity.

Results: Atomic force microscopy showed higher cantilever deflection on trypan blue-stained DM compared with control, and the difference was statistically significant (P = 0.03). Force-distance curve analysis also revealed a statistically significant increase in the Young modulus of elasticity in the trypan blue-stained samples (10.5 ± 1.4 kPa) compared with the control (5.8 ± 0.8 kPa), (P < 0.0001).

Conclusions: Our results suggest that trypan blue may decrease DM elasticity and consequently increase its stiffness. This may influence the graft adherence when used for endothelial keratoplasty.

Download full-text PDF

Source
http://dx.doi.org/10.1097/ICO.0000000000000986DOI Listing

Publication Analysis

Top Keywords

trypan blue
16
atomic force
12
descemet membrane
8
young modulus
8
trypan blue-stained
8
compared control
8
trypan
6
blue descemet
4
membrane elasticity
4
elasticity purpose
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!