Aims And Objectives: The objective of this study was to assess the clinical feasibility of generating 3D printing models of left atrial appendage (LAA) using real-time 3D transesophageal echocardiogram (TEE) data for preoperative reference of LAA occlusion.
Background: Percutaneous LAA occlusion can effectively prevent patients with atrial fibrillation from stroke. However, the anatomical structure of LAA is so complicated that adequate information of its structure is essential for successful LAA occlusion. Emerging 3D printing technology has the demonstrated potential to structure more accurately than conventional imaging modalities by creating tangible patient-specific models. Typically, 3D printing data sets are acquired from CT and MRI, which may involve intravenous contrast, sedation, and ionizing radiation. It has been reported that 3D models of LAA were successfully created by the data acquired from CT. However, 3D printing of the LAA using real-time 3D TEE data has not yet been explored.
Methods: Acquisition of 3D transesophageal echocardiographic data from 8 patients with atrial fibrillation was performed using the Philips EPIQ7 ultrasound system. Raw echocardiographic image data were opened in Philips QLAB and converted to 'Cartesian DICOM' format and imported into Mimics® software to create 3D models of LAA, which were printed using a rubber-like material. The printed 3D models were then used for preoperative reference and procedural simulation in LAA occlusion.
Results: We successfully printed LAAs of 8 patients. Each LAA costs approximately CNY 800-1,000 and the total process takes 16-17 h. Seven of the 8 Watchman devices predicted by preprocedural 2D TEE images were of the same sizes as those placed in the real operation. Interestingly, 3D printing models were highly reflective of the shape and size of LAAs, and all device sizes predicted by the 3D printing model were fully consistent with those placed in the real operation. Also, the 3D printed model could predict operating difficulty and the presence of a peridevice leak.
Conclusions: 3D printing of the LAA using real-time 3D transesophageal echocardiographic data has a perfect and rapid application in LAA occlusion to assist with physician planning and decision making.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1159/000447444 | DOI Listing |
Nat Commun
December 2024
Department of Electronic and Computer Engineering, Hong Kong University of Science and Technology, Hong Kong SAR, China.
Small-scale continuum robots hold promise for interventional diagnosis and treatment, yet existing models struggle to achieve small size, precise steering, and visualized functional treatment simultaneously, termed an "impossible trinity". This study introduces an optical fiber-based continuum robot integrated imaging, high-precision motion, and multifunctional operation abilities at submillimeter-scale. With a slim profile of 0.
View Article and Find Full Text PDFJ Integr Med
December 2024
School of Pharmacy, Shanghai University of Traditional Chinese Medicine, Shanghai 201203, China. Electronic address:
Gastric ulcer (GU) is a common digestive system disease. Acupuncture, as one of the external treatments of traditional Chinese medicine (TCM), has the characteristics of multi-target, multi-pathway and multi-level action in the treatment of GU. The relationship between meridian points and Zang-fu is an important part of the theory of TCM, which is crucial for the diagnosis and treatment of diseases.
View Article and Find Full Text PDFInt J Pharm
December 2024
Translational Pharmaceutics Research Laboratory (TPRL), Department of Pharmacy, Birla Institute of Technology and Sciences (BITS), Pilani, Hyderabad Campus, Hyderabad, Telangana 500078, India. Electronic address:
Amphotericin B eye drops (reconstituted from lyophilized Amphotericin B formulation indicated for intravenous use) is used off-label for fungal keratitis. However, the reconstituted formulation is stable only for a week, even after refrigeration. Moreover, a high dosing frequency makes it an inconvenient treatment practice.
View Article and Find Full Text PDFFront Cardiovasc Med
December 2024
Department of Cardiovascular Surgery, Xijing Hospital, Air Force Medical University, Xi'an, Shaanxi, China.
Background: To evaluate the feasibility, effectiveness and assistant effect of 3D printed aortic model in the treatment on congenital coarctation of the aorta (CoA) in adolescents and adults.
Methods: From December 2018 to December 2023, a total of 10 patients with congenital coarctation of aorta underwent percutaneous balloon dilatation covered stent implantation in the department of cardiovascular surgery, Xijing Hospital. There were 6 males and 4 females whose average age was (27.
Device
December 2024
Department of Chemical and Biomolecular Engineering, University of Delaware, Newark, DE 19716.
Modeling aerosol dynamics in the airways is challenging, and most modern personalized tools consider only a single inhalation maneuver through less than 10% of the total lung volume. Here, we present an modeling pipeline to produce a device that preserves patient-specific upper airways while approximating deeper airways, capable of achieving total lung volumes over 7 liters. The modular system, called TIDAL, includes tunable inhalation and exhalation breathing capabilities with resting flow rates up to 30 liters per minute.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!