The difficulties encountered in dealing with the bone deficient acetabulum are amongst the greatest challenges in hip surgery. Acetabular reconstruction in revision total hip arthroplasty can successfully be achieved with hemispherical components featuring a porous or roughened ingrowth surface and options for placement of multiple screws for minor acetabular defect. Acetabular component selection is mostly based on the amount of bone loss present. In the presence of combined cavitary and segmental defects without superior acetabular coverage, reconstructions with a structural acetabular allograft protected by a cage or a custom-made triflange cage have been one of preferred surgical options. The use of a cage or ring over structural allograft bone for massive uncontained defects in acetabular revision can restore host bone stock and facilitate subsequent rerevision surgery to a certain extent. But high complication rates have been reported including aseptic loosening, infection, dislocation and metal failure. On the other hand, recent literature is reporting satisfactory outcomes with the use of modular augments combined with a hemispherical shell for major acetabular defect. Highly porous metals have been introduced for clinical use in arthroplasty surgery over the last decade. Their higher porosity and surface friction are ideal for acetabular revision, optimizing biological fixation. The use of trabecular metal cups in acetabular revision has yielded excellent clinical results. This article summarizes author's experience regarding revision acetabular reconstruction options following failed hip surgery including arthroplasty.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4972873PMC
http://dx.doi.org/10.5371/hp.2016.28.1.1DOI Listing

Publication Analysis

Top Keywords

acetabular reconstruction
12
acetabular revision
12
acetabular
11
total hip
8
hip arthroplasty
8
hip surgery
8
acetabular defect
8
revision
5
reconstruction total
4
hip
4

Similar Publications

Case: Triple pelvic osteotomy (TPO) is used to treat developmental dysplasia of the hip in a pediatric population. This case report highlights a new indication for this procedure. Acetabular coverage was restored in a 9-year-old patient who experienced instability following hip hemiarthroplasty and proximal femur composite allograft implantation for the treatment of Ewing sarcoma.

View Article and Find Full Text PDF

Before patients begin out-of-bed exercises following internal fixation surgery for acetabular fractures, turning over in bed serves as a crucial intervention to mitigate complications associated with prolonged bed rest. However, data on the safety of this maneuver post-surgery are limited, and the biomechanical evidence remains unclear. This study aims to introduce a novel loading protocol designed to preliminarily simulate the action of turning over in bed and to compare the biomechanical properties of two fixation methods for acetabular fractures under this new protocol.

View Article and Find Full Text PDF

Identifying a Reliable Intra-articular Landmark to Avoid Vascular Injury During Transacetabular Screw Fixation: A 3D Computed Tomography Study.

J Am Acad Orthop Surg

February 2025

From the Department of Orthopaedic Surgery, Keck Medical Center of the University of Southern California, Los Angeles, CA (Ihn, Chung, Lovro, Patterson, Christ, and Heckmann), the Department of Orthopaedic Surgery, Mayo Clinic, Rochester, MN (Chen), the Department of Orthopaedic Surgery, University of Pittsburgh, Pittsburgh, PA (Tucker), and the Department of Radiology, Keck Medical Center of the University of Southern California, Los Angeles, CA (White, and Hwang).

Introduction: Vascular injury during acetabular screw fixation is a life-threatening complication of total hip arthroplasty. This study uses three-dimensional computed tomography to (1) measure absolute distance from the external iliac artery (EIA) to the acetabulum, (2) determine available bone stock along the EIA path, and (3) create a novel acetabular vascular risk map.

Methods: A retrospective radiographic study was conducted using three-dimensional CT.

View Article and Find Full Text PDF

Background: Dislocation remains a common complication following total hip arthroplasty (THA). Previous literature has shown that the femoral head-to-neck ratio is essential in hip motion, function, and stability. While large femoral heads and dual mobility bearings have been developed to improve stability, it remains unknown if the ratio between femoral head size to acetabular cup size also plays a role in stability.

View Article and Find Full Text PDF

Introduction: Total hip arthroplasty (THA) is recognized as one of the most effective surgical procedures for the treatment of end-stage hip arthritis. However, the increasing number of primary THA cases has led to a corresponding rise in the frequency of revision surgeries, which are often more complex and challenging due to severe acetabular bone loss. In such cases, managing Paprosky type 3A and 3B defects requires precise implant design and advanced surgical techniques.

View Article and Find Full Text PDF