Pericardiocentesis Under Continuous Ultrasonographic Guidance Using a 7 cm Micropuncture Needle.

J Invasive Cardiol

Temple University Hospital, Division of Cardiovascular Diseases, 3401 N. Broad Street (9PP), Philadelphia, PA 19140 USA.

Published: October 2016

Objectives: To compare procedural success and safety of pericardiocentesis using continuous ultrasonographic visualization of a long (7 cm) micropuncture needle to standard access with an 18 gauge needle without continuous ultrasound guidance.

Background: Current approaches to pericardiocentesis commonly utilize a large-bore 18 gauge needle for access without allowing for continuous visualization of needle entry into the pericardial space.

Methods: We included all consecutive patients at our institution who underwent pericardiocentesis between November 1, 2011 and March 3, 2016. A total of 21 patients (group 1) underwent pericardiocentesis using a 7 cm micropuncture needle inserted under continuous ultrasonographic guidance, while 51 patients (group 2) underwent pericardiocentesis, mostly with an 18 gauge needle (92%), following preprocedural echocardiography only. The primary endpoint was successful placement of a drain into the pericardial space.

Results: The primary endpoint was similar between group 1 and group 2 (100% vs 94%, respectively; P=.26). Successful drainage of pericardial fluid was achieved in 95% of patients in group 1 and in 98% in group 2 (P=.88). The amount of pericardial fluid drained in each group was similar (640 mL vs 557 mL, respectively; P=.26). No procedure-related complications occurred in group 1, compared with 2 cases of right ventricular perforation that occurred in group 2. In-hospital mortality and length of stay were similar.

Conclusion: This study suggests that an ultrasound-mounted micropuncture needle allows for safe and effective pericardiocentesis. This technique may provide a safer alternative to the standard use of an 18 gauge needle.

Download full-text PDF

Source

Publication Analysis

Top Keywords

micropuncture needle
16
gauge needle
16
continuous ultrasonographic
12
underwent pericardiocentesis
12
patients group
12
needle
9
group
9
pericardiocentesis continuous
8
ultrasonographic guidance
8
group underwent
8

Similar Publications

[Hot topic: indications and contraindications for ultrasound-guided biopsy of thyroid nodules and cervical lymph nodes].

Zhonghua Nei Ke Za Zhi

February 2025

Department of Ultrasound Medicine, China-Japan Friendship Hospital, Beijing100029, China Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing100730, China National Respiratory Medicine Center, National Key Laboratory of Respiratory and Comorbidity, National Respiratory Medical Center National Clinical Research Center, Respiratory Diseases Respiratory Research Institute of Chinese Academy of Medical Sciences, Respiratory Center of China-Japan Friendship Hospital, Beijing100029, China.

View Article and Find Full Text PDF

Background: Prostate cancer (PCa) is definitively diagnosed by systematic prostate biopsy (SBx) with 13 cores. This method, however, can increase the risk of urinary retention, infection and bleeding due to the excessive number of biopsy cores.

Methods: We retrospectively analyzed 622 patients who underwent SBx with prostate multiparametric MRI (mpMRI) from two centers between January 2014 to June 2022.

View Article and Find Full Text PDF

Background: Traditional freehand puncture relies on non-real-time computed tomography (CT) images, which significantly affects the accuracy of puncturing targets in the lower lung lobes with respiratory motion. This study aims to assess the safety and feasibility of a teleoperated robotic system and low-dose CT for the accurate real-time puncture of targets in the lungs of live pigs during breathing under fluoroscopic guidance.

Methods: Two puncture methods were analyzed: freehand and robot-assisted.

View Article and Find Full Text PDF

Objectives: Vascular access thrombosis (VAT) is a common complication in patients with end-stage renal disease (ESRD), significantly impacting hemodialysis efficacy and patient survival. Currently, temporary dialysis access is typically established deep vein catheterization (VC), however, this method is highly invasive and associated with risks of infection and other complications. This study aims to explore the feasibility of using direct anastomosis indwelling needle puncture (DAINP) for temporary dialysis access.

View Article and Find Full Text PDF

Morphea is a chronic inflammatory fibrosing disorder. Since fibrosis is the hallmark of both scars and morphea, our attention was raised for the possible use of Fractional Ablative CO lasers and microneedling as treatment modalities for morphea. To compare the efficacy and safety of Fractional Ablative CO lasers and microneedling in the treatment of morphea.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!