Background: To assess the corneal diameter and its associations in children.
Design: Cross-sectional school-based study.
Participants: Six thousand twenty-six children aged 4-18 years were included in the Shandong Children Eye Study.
Methods: Horizontal corneal diameter was measured by laser interferometry-based ocular biometry.
Main Outcome Measures: Horizontal corneal diameter.
Results: Corneal diameter measurements were available for 5970 (99.1%) children. In multivariate analysis, larger horizontal corneal diameter (mean: 12.02 ± 0.38 mm; range: 10.1-15.0 mm) was associated with longer corneal curvature radius longer axial length, male gender, younger maternal age, rural region of habitation and lower intraocular pressure measurements. Higher prevalence of abnormally large corneas (macrocorneas; horizontal diameter ≥ 12.76 mm; mean value +2 × standard deviations; mean: 2.6%; 95% CI: 2.2, 3.0) was associated with longer corneal curvature radius, longer axial length, younger maternal age and male gender. Higher prevalence of abnormally small corneas (horizontal diameter ≤ 11.24mm; mean value -2 × standard deviations; mean: 2.4%; 95% CI: 2.0, 2.8) was correlated with shorter corneal curvature radius, shorter axial length and urban region of habitation. Neither abnormally large nor small corneas were correlated with time spent indoors/outdoors.
Conclusions: In 4 to 18-year-old children, larger corneal diameter was associated most strongly with flatter corneal curvature, followed by longer axial length and male gender. Corneal diameter was independent of age beyond an age of 4 years. Abnormally large and abnormally small corneas may be defined as being ≥12.76 and ≤11.24 mm in diameter, respectively. Corneal diameter was not correlated with time spent indoors/outdoors.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/ceo.12821 | DOI Listing |
Clin Optom (Auckl)
December 2024
Department of Mathematical Sciences, Worcester Polytechnic Institute, Worcester, MA, 01609, USA.
Purpose: Retrospective study to review scleral lens outcomes in the pediatric population over a 21-year period, at a single clinical center.
Results: A total of 209 pediatric eyes (108 males and 101 females), distributed between 97 right and 112 left eyes, of which 147 eyes had ocular surface disease and 62 eyes had irregular cornea/refractive conditions, were treated with scleral lenses over a 21-year period. The mean age at the time of treatment initiation was 10.
Eye Contact Lens
November 2024
Department of Ophthalmology (E.B.V.), Kocaeli Kandıra M. Kazım Dinç State Hospital, Kocaeli, Turkey; Department of Ophthalmology (S.A.T.), Marmara University Medical School, Istanbul, Turkey; and Department of Ophthalmology and Visual Sciences (A.E.T.), West Virginia University Eye Institute, Morgantown, WV.
Purpose: The objective of this study was to compare the changes in postlens fluid optical density, timing and quantity of lens settling, and the clinical performance between two different mini-scleral lenses.
Methods: Seventeen eyes of 10 patients with keratoconus were fitted with a 15-mm mini-scleral lens (AirKone Scleral Lenses; Laboratoire LCS, Normandy, France), and 15 eyes of 10 patients with keratoconus were fitted with 16.5-mm mini-scleral lenses (Misa Lenses; Microlens Contactlens Technology, Arnhem, The Netherlands).
Clin Ophthalmol
December 2024
Département de Recherche Clinique, Institut Ophtalmologique de l'Ouest (IOO) Jules Verne, Nantes, France.
Purpose: To evaluate clinical outcomes obtained after cataract surgery involving the implantation of a trifocal hydrophobic intraocular lens (IOL) and to determine if pupil size and the corneal aberrometric profile correlate to visual acuity at different distances.
Methods: 49 patients (98 eyes) underwent bilateral cataract surgery with the placement of FineVision HP IOLs for presbyopia and were assessed at 1- and 3- to 6-months post-surgery. Postoperatively, refraction, monocular and binocular uncorrected and corrected distance visual acuity (UDVA and CDVA), uncorrected intermediate visual acuity (UIVA), uncorrected near visual acuity (UNVA) and the binocular defocus curve were measured.
J Photochem Photobiol B
December 2024
Anne Bates Leach Eye Center, Bascom Palmer Eye Institute, Department of Ophthalmology, University of Miami Miller School of Medicine, Miami, FL, United States of America; Ocular Microbiology Laboratory, Bascom Palmer Eye Institute, Department of Ophthalmology, University of Miami Miller School of Medicine, Miami, FL, United States of America.
Introduction: Fungal keratitis is a leading cause of corneal blindness, with current antifungal treatments having limited efficacy. One promising treatment modality is Rose Bengal (RB) photodynamic antimicrobial therapy (PDAT) that has shown mixed success against fungal keratitis. Therefore, there is a need to explore the antimicrobial efficacy of other green-light activated photosensitizers that have deep penetration in the cornea to combat the deep fungal infections, such as Erythrosin B (EB) and Eosin Y (EY).
View Article and Find Full Text PDFEye Vis (Lond)
January 2025
Contact Lens and Visual Optics Laboratory, Optometry and Vision Science, Centre for Vision and Eye Research, Queensland University of Technology, Brisbane, Australia.
Purpose: To explore the associations between myopia defocus dosage (MDD), aberration coefficients (primary spherical aberration and coma), and axial elongation in children undergoing orthokeratology (ortho-k) with back optic zone diameters (BOZD) of 5 mm and 6 mm over 2 years.
Methods: Data from 80 participants from two ortho-k studies were analyzed: 22 and 58 children wore lenses with 5-mm and 6-mm BOZD, respectively. Four MDD metrics were calculated from corneal topography data over a 5-mm pupil for the 1-month and 24-month visits: the circumferential, flat, steep, and volumetric MDD.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!