This study focused on the development of novel coating formulations for stainless steel microneedles against influenza A virus. With in vitro studies, various viscosity enhancers and stabilizers were screened based on the hemagglutination activity of the vaccine, which was coated and dried onto a stainless steel chip at room temperature for 1 day. Following the long-term storage test, the hemagglutination activity and particle size of the vaccine, which was formulated with conventional or methylcellulose or hydroxyethyl cellulose and dried onto the microneedle, were monitored. Next, to evaluate the in vivo immunogenicity and protection effect of each dried vaccine formulation, mice were immunized by the antigen-coated microneedle, which had either the conventional or the proposed formulation. Two novel formulations were chosen in the preliminary screening, and in further evaluations, they exhibited a 20 % higher HA activity during storage for 3 months, and no aggregation was observed during storage after drying. In a mouse model, the microneedle with the novel formulation elicited a higher level of IgG and IgG2a was more prevalent in the IgG isotype profile. In addition, mice immunized with the HEC-coated microneedle survived with small weight loss (>90 %) against lethal challenge infection. Overall, the novel formulation hydroxyethyl cellulose preserved significantly higher HA activity during the production and storage of the microneedle as well as improved the in vivo immunogenicity of the vaccine.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s13346-016-0321-zDOI Listing

Publication Analysis

Top Keywords

stainless steel
12
development novel
8
novel coating
8
coating formulations
8
hemagglutination activity
8
hydroxyethyl cellulose
8
vivo immunogenicity
8
mice immunized
8
higher activity
8
novel formulation
8

Similar Publications

Aqueous zinc-ion batteries are an appealing electrochemical energy storage solution due to their affordability and safety. Significant attention has been focused on vanadium oxide cathode materials for ZIBs, owing to their high specific capacity, unique layered or tunnel structures, and low cost. Compared to traditional methods for preparing and assembling electrode materials, direct current (DC) magnetron sputtering allows direct synthesis and uniform deposition on current collectors, offering advantages such as simplicity, mild reaction conditions, and strong film adhesion.

View Article and Find Full Text PDF

Listeria monocytogenes raises major challenges for the food industry. Due to its capacity to form biofilms, this pathogen can persist in processing environments and contaminate the final products. Neutral electrolyzed water (NEW) may offer a promising and eco-friendly method for controlling L.

View Article and Find Full Text PDF

Objectives: Apical root resorption and alveolar bone loss are potential complications associated with orthodontic treatment. This study aimed to assess apical root resorption and alveolar bone height following orthodontic treatment of moderate crowding with labial vs. lingual fixed appliances using CBCT imaging.

View Article and Find Full Text PDF

Design of a wasp-inspired biopsy needle capable of self-propulsion and friction-based tissue transport.

Front Bioeng Biotechnol

January 2025

Department of BioMechanical Engineering, Bio-Inspired Technology Group, Faculty of Mechanical Engineering, Delft University of Technology, Delft, Netherlands.

Percutaneous pancreatic core biopsy is conclusive but challenging due to large-diameter needles, while smaller-diameter needles used in aspiration methods suffer from buckling and clogging. Inspired by the ovipositor of parasitic wasps, which resists buckling through self-propulsion and prevents clogging via friction-based transport, research has led to the integration of these functionalities into multi-segment needle designs or tissue transport system designs. This study aimed to combine these wasp-inspired functionalities into a single biopsy needle by changing the interconnection of the needle segments.

View Article and Find Full Text PDF

Assessment on surface integrity in electrochemical grinding of AISI 304.

Heliyon

January 2025

Advanced Technologies of Machine Tools (ATMT) Lab, Faculty of Mechanical Engineering, Tarbiat Modares University, Tehran, Iran.

Electrochemical grinding (ECG) offers advantages such as burr-free and stress-free material removal. Despite its proven potential, limited research has addressed the comprehensive effects of key process parameters on the surface integrity of AISI 304 stainless steel, particularly for applications requiring high-quality finishes, such as medical components. This study bridges this gap by systematically investigating the influence of ECG key parameters including voltage, rotational speed, and electrolyte concentration on main surface integrity parameters including current density, surface roughness, microhardness, and surface texture.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!