Bacterial endotoxins, DNA, live viruses, and viral proteins derived from bacterial and baculovirus (BV) expression vectors employed in recombinant protein production contaminate the final product. Density gradient centrifugation is commonly used to partially purify oligomeric proteins, but impurities from the expression system still remain. We describe a simple and rapid ultrafiltration method for final purification of rotavirus VP6 oligomeric nanotubes and nanospheres. Contamination originating from the BV vector used in VP6 production was undetectable. The method is highly efficient, fast and inexpensive and can be used for a small-scale laboratory purification of VP6 protein to replace technically demanding multi-step chromatographic procedures.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00705-016-2991-8DOI Listing

Publication Analysis

Top Keywords

ultrafiltration method
8
purification rotavirus
8
rotavirus vp6
8
vp6 oligomeric
8
oligomeric proteins
8
simple efficient
4
efficient ultrafiltration
4
method purification
4
vp6
4
proteins bacterial
4

Similar Publications

The influence of cardiopulmonary bypass residual volume processing technique on blood management in cardiac surgical patients.

Perfusion

January 2025

Congenital Heart Center, Division of Cardiovascular Surgery, Departments of Surgery and Pediatrics, University of Florida, Gainesville, FL, USA.

Post-cardiopulmonary bypass (CPB) blood processing is an important component of blood management during cardiac surgery. The purpose of this study is to evaluate several methods of processing post-CPB residual blood. Using a multi-institutional national database (SpecialtyCare Operative Procedural rEgistry [SCOPE]), 77,591 cardiac surgical operations performed in adults (>18 years) between January 2017 and September 2022 were reviewed.

View Article and Find Full Text PDF

Background: Peritoneal dialysis (PD) is an important modality of renal replacement therapy (RRT). Peritonitis and ultrafiltration failure are complications that have a long-term impact on PD patients. Besides touch contamination, procedural errors and clinical reasons of peritonitis, contaminants, and constituents of peritoneal dialysis fluids (PDFs) have been implicated in causing peritonitis and ultrafiltration failure.

View Article and Find Full Text PDF

Novel Ultrafiltration Polyethersulfone Membranes Blended with Carrageenan.

Polymers (Basel)

January 2025

Qatar Environment and Energy Research Institute, Hamad Bin Khalifa University, Qatar Foundation, Doha P.O. Box 34110, Qatar.

The development of ultrafiltration (UF) polymeric membranes with high flux and enhanced antifouling properties bridges a critical gap in the polymeric membrane fabrication research field. In the present work, the preparation of novel PES membranes incorporated with carrageenan (CAR), which is a natural polymer derived from edible red seaweed, is reported for the first time. The PES/CAR membranes were prepared by using the nonsolvent-induced phase separation (NIPS) method at 0.

View Article and Find Full Text PDF

Methylglyoxal-Stimulated Mesothelial Cells Prompted Fibroblast-to-Proto-Myofibroblast Transition.

Int J Mol Sci

January 2025

Graduate Institute of Veterinary Medicine, School of Veterinary Medicine, National Taiwan University, Taipei 10617, Taiwan.

During long-term peritoneal dialysis, peritoneal fibrosis (PF) often happens and results in ultrafiltration failure, which directly leads to the termination of dialysis. The accumulation of extracellular matrix produced from an increasing number of myofibroblasts was a hallmark characteristic of PF. To date, glucose degradation products (GDPs, i.

View Article and Find Full Text PDF

Membrane Treatment to Improve Water Recycling in an Italian Textile District.

Membranes (Basel)

January 2025

Department of Civil and Environmental Engineering, University of Florence, Via di Santa Marta 3, 50139 Firenze, Italy.

The textile district of Prato (Italy) has developed a wastewater recycling system of considerable scale. The reclaimed wastewater is characterized by high levels of hardness (32 °F on average), which precludes its direct reuse in numerous wet textile processes (e.g.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!