A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Air-Bone Gaps Contribute to Functional Hearing Preservation in Cochlear Implantation. | LitMetric

Air-Bone Gaps Contribute to Functional Hearing Preservation in Cochlear Implantation.

Otol Neurotol

*Department of Otolaryngology †Department of Audiology, University of Colorado School of Medicine, Aurora, Colorado.

Published: October 2016

Objective: To examine the incidence and effect of postoperative air-bone gaps in subjects who received cochlear implants for the purpose of hearing preservation.

Study Design: Prospective, multicenter, nonrandomized, repeated measures within subject design.

Setting: Ten tertiary care institutions.

Patients: Fifty adults participating in a multicenter clinical trial of the Cochlear Nucleus Hybrid implant system.

Intervention(s): Cochlear implantation with Hybrid L24 electrode. Audiometric testing including air and bone conductive thresholds and tympanometry preoperatively and at multiple time points postoperatively for 1 year.

Main Outcome Measure(s): Average air-bone gaps (ABG) and percentage of patients with ABGs (≥15 dB HL) measured for each time point for 1 year postoperatively at 250, 500, and 1000 Hz. Correlation of tympanograms and ABGs.

Results: The mean ABGs at 250, 500, and 1000 Hz increased postoperatively (p <0.05). The percentage of patients found to have an ABG (≥15 dB HL) also increased postoperatively (p <0.05). ABGs persisted and were present at 1 year in >60% of patients at 250 Hz, in >38% at 500 Hz, and in >50% at 1000 Hz in those with residual hearing. No significant relationships were found between abnormal tympanograms and ABG.

Conclusion: The incidence of ABGs postoperatively is higher than previously expected and does not correlate to abnormalities on tympanometry. ABGs can adversely affect the fitting of postoperative residual hearing and associated functional benefit. Additionally, intraoperative strategies should be used to potentially reduce ABGs, and bone conduction thresholds should be measured postoperatively.

Download full-text PDF

Source
http://dx.doi.org/10.1097/MAO.0000000000001171DOI Listing

Publication Analysis

Top Keywords

air-bone gaps
12
cochlear implantation
8
250 500
8
500 1000 hz
8
residual hearing
8
postoperatively
5
abgs
5
gaps contribute
4
contribute functional
4
hearing
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!