Purpose: The purpose of this study is to evaluate the pharmacokinetics, immunogenicity, safety, and tolerability of guselkumab, a human monoclonal antibody with high affinity and specificity for binding to interleukin-23.
Methods: In this first-in-human, phase 1, randomized study, a single intravenous (IV; 0.03-10 mg/kg) or subcutaneous (SC; 10-300 mg) dose of guselkumab was administered to 47 healthy subjects, and a single SC dose (placebo, 10, 30, 100, 300 mg) was administered to 24 patients with moderate-to-severe psoriasis.
Results: Mean maximum observed serum concentration and area under the zero-to-infinity serum concentration-time curve of guselkumab increased in an approximately dose-proportional manner over the dose range of 0.03-10 mg/kg following a single IV administration or 10-300 mg following a single SC administration. Mean clearance and volume of distribution ranged from 3.62-6.03 mL/day/kg and 99.38-123.22 mL/kg, respectively. Mean half-life ranged from 12 to 19 days in healthy subjects and patients with psoriasis. Among guselkumab-treated subjects/patients, 1/30 (3.3 %) healthy subjects in the IV group, 0/6 healthy subjects in the SC group, and 1/20 (5.0 %) patients with psoriasis tested positive for antibodies to guselkumab. No clinically significant adverse events were identified in this study.
Conclusion: Guselkumab pharmacokinetic profiles were generally comparable between healthy subjects and patients with psoriasis. Guselkumab, administered as an IV infusion or SC injection, was well tolerated in healthy subjects and patients with psoriasis.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00228-016-2110-5 | DOI Listing |
This study aims to evaluate cerebrospinal fluid (CSF) flow dynamics within ventricles, and the subarachnoid space (SAS) using the velocity selective spin labeling (VSSL) MRI method with Fourier-transform-based velocity selective inversion preparation. The study included healthy volunteers who underwent MRI scanning with specific VSSL parameters optimized for CSF flow quantification. The VSSL sequence was calibrated against phase-contrast MRI (PC-MRI) to ensure accurate flow velocity measurements.
View Article and Find Full Text PDFRev Bras Ortop (Sao Paulo)
December 2024
Departamento de Ortopedia, Traumatologia e Cirurgia da Mão, Faculdade de Medicina, Ankara University, Altındağ, Ankara, Turquia.
To assess the efficacy of distal radius volar plates in cases involving dorsal fragments at the Ulnar Corner (UC) and Lister Tubercle (LT). A retrospective study that included patients with distal radius fractures (DRFs) featuring UC and LT dorsal fragments treated with volar plates. The exclusion criteria comprised lunate facet fractures, UC fragment ratio below 25%, and patients treated with dorsal plates.
View Article and Find Full Text PDFArch Physiother
December 2024
Department of Physiotherapy, Faculty of Medicine and Health Sciences, Universitat Internacional de Catalunya (UIC), Barcelona - Spain.
Introduction: The modified shuttle test-15 (MST-15) is a valid alternative for assessing exercise capacity when a cardiopulmonary exercise testing is not feasible. This study aims to describe the percentage of healthy and cystic fibrosis (CF) children and adolescents reaching the MST-15 ceiling. Additionally, it examines associations between MST-15 distance and demographic, anthropometric, and lung function data.
View Article and Find Full Text PDFJ Diabetes Sci Technol
December 2024
Edward Hines, Jr. VA Hospital, Hines, IL, USA.
Background: Treatment of diabetes and its complications is a primary health care expense. Up to 25% of people with diabetes will develop diabetic foot ulcers (DFUs). Removable cast walker (RCW) boots commonly prescribed for DFU treatment, promote healing, and provide offloading and wound protection.
View Article and Find Full Text PDFIntroduction: During centrifuge-simulated suborbital spaceplane flights, launch and re-entry frequently cause visual symptoms, and G-induced loss of consciousness can occur. G-related effects may be more prominent during re-entry from microgravity on actual flights. A modified anti-G maneuver that does not involve a breath strain and is suitable for members of the public may be effective against these effects.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!