Background: Recurrent legionella outbreaks at one and the same location are common. We have identified a single Legionella pneumophila genotype associated with recurrent Legionella outbreaks over 6 years.
Methods: Field emergency surveys following Legionella outbreaks were performed on a vessel in 2008, 2009 and 2013. Water samples from both the distribution and technical parts of the potable water system were analyzed with respect to L. pneumophila [Real-Time PCR, cultivation, serotyping and genotyping (PFGE)] and free-living amoebae, (FLA).
Results: Legionella pneumophila serogroup 1 was present in the ship's potable water system during every outbreak. Genotyping of the 2008 survey material showed two separate PFGE genotypes while those in 2009 and 2013 demonstrated the presence of only one of the two genotypes. FLA with intracellular L. pneumophila of the same genotype were also detected. Analyses of the freshwater system on a ship following three separate Legionella outbreaks, for L. pneumophila and FLAs, revealed a single L. pneumophila genotype and FLA (Hartmanella).
Conclusions: It is reasonable to assume that the L. pneumophila genotype detected in the freshwater system was the causal agent in the outbreaks onboard. Persistence of an apparently low-pathogenic L. pneumophila genotype and FLA in a potable water system represent a potential risk for recurrent outbreaks.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4981653 | PMC |
http://dx.doi.org/10.3402/mehd.v27.31148 | DOI Listing |
J Water Health
November 2024
Department of Infectious Diseases, Kobe Institute of Health, Kobe, Japan E-mail:
Pathogens
September 2024
Interdisciplinary Department of Medicine, University of Bari Aldo Moro, Piazza G. Cesare 11, 70124 Bari, Italy.
Wastewater treatment plants (WWTPs) provide optimal conditions for the environmental spread of . As part of the Evaluation of Sanitary Risk Related to the Discharge of Wastewater to the Ground (SCA.Re.
View Article and Find Full Text PDFMicroorganisms
June 2024
Legionella Reference Laboratory, National Centre for Microbiology, Instituto de Salud Carlos III, 28220 Madrid, Spain.
Although cases of Legionnaires' disease are notifiable, data on the phenotypic and genotypic characterisation of clinical isolates are limited. This retrospective study aims to report the results of the characterisation of clinical isolates in Spain from 2012 to 2022. Monoclonal antibodies from the Dresden panel were used for phenotypic identification of .
View Article and Find Full Text PDFPLoS One
July 2024
Department of Agricultural, Food, Environmental and Animal Science (Di4A), University of Udine, Udine, Italy.
Given the recent global surge in Legionnaires' disease cases, the monitoring of Legionella pneumophila becomes increasingly crucial. Epidemiological cases often stem from local outbreaks rather than widespread dissemination, emphasizing the need to study the characteristics of this pathogen at a local level. This study focuses on isolates of L.
View Article and Find Full Text PDFEuro Surveill
May 2024
Department of Infectious Diseases, Public Health Service region Utrecht (GGD), Zeist, the Netherlands.
Wastewater treatment plants (WWTPs) are increasingly identified as Legionnaires' disease (LD) sources. An outbreak investigation was initiated following five LD cases reported in September 2022 in Houten, the Netherlands. Case identification was based on the European LD case definition, with symptom onset from 1 September 2022, residence in or within 5 km of Houten, or visit to Houten within the incubation period, without other likely sources.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!