A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Accuracy of Cone Beam Computed Tomography, Photostimulable Phosphor Plate Digital Radiography and Conventional Radiography for Detection of Artificial Cancellous Bone Defects. | LitMetric

Objectives: The optimal goal of radiography is to provide high-quality diagnostic images with the least patient radiation dose. The aim of this study was to evaluate the accuracy of cone-beam computed tomography (CBCT) and intraoral photostimulable phosphor plate (PSP) digital and film-based conventional radiography for detection of artificial cancellous bone defects.

Materials And Methods: Five dry human mandibles were used in this study. The mandibles were placed inside a water bath made of plexiglass plates; then PSP and CBCT scans were obtained. The mandibles were cut by a coping saw in buccolingual dimension and oval defects measuring 6.1×6.1 mm, 3×6.1 mm and 4×4 mm were created by a milling machine in the spongy bone. After fixing the two parts together (buccal and lingual), radiographs were repeated. Presence or absence of defects on images was evaluated and recorded by the two observers. Using SPSS 16, compatibility level, sensitivity, specificity and receiver operating curve (ROC) analysis were determined for each observer.

Results: The intraobserver agreement in all three imaging modalities was low to moderate (kappa≤0.613). The inter-observer agreement in all the three imaging modalities was moderate (kappa=0.406). The area under the curve (AUC) of the imaging modalities in each observation was not significantly different. The area under the curve based on defect size for the two observers was not significantly different either.

Conclusion: Defects confined to spongy bone can be identified on film and PSP radiographs and CBCT scans. However, interpretation of PSP images and CBCT scans needs greater expertise and skills.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4977403PMC

Publication Analysis

Top Keywords

cbct scans
12
imaging modalities
12
computed tomography
8
photostimulable phosphor
8
phosphor plate
8
conventional radiography
8
radiography detection
8
detection artificial
8
artificial cancellous
8
cancellous bone
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!