A self-built monitoring sampling system on particulate matters and water soluble ions emitted from stationary combustion sources and a size separated sampling system on particulate matters based on FPS4000 and ELPI + were applied to test particulate matters in fumes of typical stationary combustion sources in Beijing. The results showed that the maximum concentration of total particulate matters in fumes of stationary combustion sources in Beijing was 83.68 mg · m⁻³ in standard smoke oxygen content and the minimum was 0.12 mg · m⁻³. And particle number concentration was in the 10⁴-10⁶ cm⁻³ number of grade. Both mass and number concentration ranking order of particulate matters emitted from stationary combustion sources in Beijing was: heating gas fired boilers < power plant coal fired boilers < heating coal fired boilers. And two or three peaks existed under 1 µm of particulate size for both number size distribution and mass size distribution. The number concentration for PM₂.₅ accounted for over 99.8% of that for PM₁₀ and that for PM₀.₁ accounted for over 83% of that for PM₂.₅. But the proportions of PM₀.₁, and PM₂.₅ in PM₁₀ were significantly lower in quality analysis,the proportion of PM₂.₅ in PM₁₀ was about 82%, and that of PM₀.₁ in PM₂.₅ was about 27%-33%.