We propose a measurement system using dual-wavelength digital holography and low-coherence interferometry to measure micro- and nanostructure surface heights. To achieve an extended axial step-measurement range and better image quality, a single light-emitting diode generates two distinct light sources by filtering different center wavelengths and narrower bandwidths. The system can measure surface profile with higher step heights and lower speckle noise in a large field-of-view. Using single-source lighting and a simple configuration, the method supports compactly configured and lower-cost surface-topography measurement systems applicable in various fields. Experimental results for a standard step sample verify the system's performance.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1364/OE.24.018408 | DOI Listing |
Laser Photon Rev
October 2024
Harvard Medical School, Boston, MA 02114, USA; Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, MA 02114, USA; Department of Cardiology, Erasmus Medical Center, Rotterdam GD3015, The Netherlands; Institute for Medical Engineering and Science, Massachusetts Institute of Technology, Cambridge, MA 02142, USA.
Photoacoustic microscopy (PAM) is a high-resolution and non-invasive imaging modality that provides optical absorption contrast. By employing dual- or multiple-wavelength excitation, PAM extends its capabilities to offer valuable spectroscopic information. To achieve efficient multispectral PAM imaging, an essential requirement is a light source characterized by a high repetition rate and switching rate, a ≈microjoule pulse energy, and a ≈nanosecond pulse duration.
View Article and Find Full Text PDFWe propose a dual-wavelength scheme for a clipping-avoidance photonic analog-to-digital converter (PADC) operating at the sub-Nyquist sampling rate. The scheme utilizes two characteristics, the phase-wrapping feature of a PADC and the wavelength-sensitive feature of a phase modulator, equivalently performing a dual-modulus (DM) modulo operation to avoid clipping. Coupled with an unwrapping algorithm based on the Chinese remainder theorem (CRT), the proposed scheme enables signal reconstruction from the processed signals independent of the sampling rate.
View Article and Find Full Text PDFTo address the problem of the time-sharing recording of dual-wavelength low-coherence holograms while avoiding the use of customized achromatic optical elements, a snapshot dual-wavelength digital holography with LED and laser hybrid illumination is proposed. In this method, the parallel phase-shifting method is firstly employed to suppress zero-order and twin-image noise, and to record a LED hologram with low speckle noise and full field of view. Secondly, another laser hologram with a different center wavelength affected by speckle noise is recorded simultaneously using the spatial multiplexing technique.
View Article and Find Full Text PDFWe demonstrate lensless single-shot dual-wavelength digital holography for high-speed 3D imaging in industrial inspection. Single-shot measurement is realized by combining off-axis digital holography and spatial frequency multiplexing of the two wavelengths on the detector. The system has 9.
View Article and Find Full Text PDFLight Sci Appl
May 2024
Department of Biomedical Engineering, College of Engineering, City University of Hong Kong, Kowloon, Hong Kong SAR, China.
Using photodynamic therapy (PDT) to treat deep-seated cancers is limited due to inefficient delivery of photosensitizers and low tissue penetration of light. Polymeric nanocarriers are widely used for photosensitizer delivery, while the self-quenching of the encapsulated photosensitizers would impair the PDT efficacy. Furthermore, the generated short-lived reactive oxygen spieces (ROS) can hardly diffuse out of nanocarriers, resulting in low PDT efficacy.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!