Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Introduction: screening all unscheduled older adults for delirium is recommended in national guidelines, but there is no consensus on how to perform initial assessment.
Aim: to evaluate the test accuracy of five brief cognitive assessment tools for delirium diagnosis in routine clinical practice.
Methods: a consecutive cohort of non-elective, elderly care (older than 65 years) hospital inpatients admitted to a geriatric medical assessment unit of an urban teaching hospital. Reference assessments were clinical diagnosis of delirium performed by elderly care physicians. Routine screening tests were: Abbreviated Mental Test (AMT-10, AMT-4), 4 A's Test (4AT), brief Confusion Assessment Method (bCAM), months of the year backwards (MOTYB) and informant Single Question in Delirium (SQiD).
Results: we assessed 500 patients, mean age 83 years (range = 66-101). Clinical diagnoses were: 93 of 500 (18.6%) definite delirium, 104 of 500 (20.8%) possible delirium and 277 of 500 (55.4%) no delirium; 266 of 500 (53.2%) were identified as definite or possible dementia. For diagnosis of definite delirium, AMT-4 (cut-point < 3/4) had a sensitivity of 92.7% (95% confidence interval (CI): 84.8-97.3), with a specificity of 53.7% (95% CI: 48.1-59.2); AMT-10 (<4/10), MOTYB (<4/12) and SQiD showed similar performance. bCAM had a sensitivity of 70.3% (95% CI: 58.5-80.3) with a specificity of 91.4% (95% CI: 87.7-94.3). 4AT (>4/12) had a sensitivity of 86.7% (95% CI: 77.5-93.2) and specificity of 69.5% (95% CI: 64.4-74.3).
Conclusions: short screening tools such as AMT-4 or MOTYB have good sensitivity for definite delirium, but poor specificity; these tools may be reasonable as a first stage in assessment for delirium. The 4AT is feasible and appears to perform well with good sensitivity and reasonable specificity.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1093/ageing/afw130 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!