Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: To assess retinal sensitivity after selective retina therapy (SRT) in patients with central serous chorioretinopathy (CSCR).
Methods: Seventeen eyes of 17 patients with CSCR lasting longer than 3 months were treated with SRT (wavelength 527 nm Nd: YLF laser, 50-150 μJ/pulse, spot diameter 200 μm). Measurement of best-corrected visual acuity (BCVA), optical coherence tomography, fluorescence angiography, and microperimetry (MAIA™) were conducted before, and 1 and 3 months after treatment. Microperimetry was performed in the central 10° of the macula, and at the test spots applied near the vascular arcade for energy titration. In addition to the treatment effect, all test irradiation spots were thoroughly analyzed with regard to their sensitivity changes.
Results: The mean logMAR BCVA had improved from 0.06 to 0.02 after 1 month (p = 0.11) and to 0.03 after 3 months (p = 0.003). Eleven out of 17 eyes (64.7%) showed complete resolution of subretinal fluid after 3 months. Retinal sensitivity in the central 10° increased after 1 month (median: 25.9 dB) and 3 months (26.6 dB) as compared with that before treatment (23.0 dB) (p < 0.001). Analysis of the test spots revealed a slight decrease in retinal sensitivity after 1 month (ΔdB = -0.5 ± 2.1, p = 0.006), while there was no significant difference from baseline after 3 months (ΔdB = -0.3 ± 2.2, p = 0.09). No correlation was found between laser energy and the change in focal retinal sensitivity.
Conclusions: Results suggest that SRT is a safe and effective treatment for persistent CSCR and does not leave permanent scotoma regardless of irradiation energy in the therapeutic range.