OBJECTIVE Historically, performing neurosurgery with the patient in the sitting position offered advantages such as improved visualization and gravity-assisted retraction. However, this position fell out of favor at many centers due to the perceived risk of venous air embolism (VAE) and other position-related complications. Some neurosurgical centers continue to perform sitting-position cases in select patients, often using modern monitoring techniques that may improve procedural safety. Therefore, this paper reports the risks associated with neurosurgical procedures performed in the sitting position in a modern series. METHODS The authors reviewed the anesthesia records for instances of clinically significant VAE and other complications for all neurosurgical procedures performed in the sitting position between January 1, 2000, and October 8, 2013. In addition, a prospectively maintained morbidity and mortality log of these procedures was reviewed for instances of subdural or intracerebral hemorrhage, tension pneumocephalus, and quadriplegia. Both overall and specific complication rates were calculated in relation to the specific type of procedure. RESULTS In a series of 1792 procedures, the overall complication rate related to the sitting position was 1.45%, which included clinically significant VAE, tension pneumocephalus, and subdural hemorrhage. The rate of any detected VAE was 4.7%, but the rate of VAE requiring clinical intervention was 1.06%. The risk of clinically significant VAE was highest in patients undergoing suboccipital craniotomy/craniectomy with a rate of 2.7% and an odds ratio (OR) of 2.8 relative to deep brain stimulator cases (95% confidence interval [CI] 1.2-70, p = 0.04). Sitting cervical spine cases had a comparatively lower complication rate of 0.7% and an OR of 0.28 as compared with all cranial procedures (95% CI 0.12-0.67, p < 0.01). Sitting cervical cases were further subdivided into extradural and intradural procedures. The rate of complications in intradural cases was significantly higher (OR 7.3, 95% CI 1.4-39, p = 0.02) than for extradural cases. The risk of VAE in intradural spine procedures did not differ significantly from sitting suboccipital craniotomy/craniectomy cases (OR 0.69, 95% CI 0.09-5.4, p = 0.7). Two cases (0.1%) had to be aborted intraoperatively due to complications. There were no instances of intraoperative deaths, although there was a single death within 30 days of surgery. CONCLUSIONS In this large, modern series of cases performed in the sitting position, the complication rate was low. Suboccipital craniotomy/craniectomy was associated with the highest risk of complications. When appropriately used with modern anesthesia techniques, the sitting position provides a safe means of surgical access.

Download full-text PDF

Source
http://dx.doi.org/10.3171/2016.5.JNS152328DOI Listing

Publication Analysis

Top Keywords

sitting position
28
performed sitting
16
complications neurosurgical
12
neurosurgical procedures
12
procedures performed
12
clinically vae
12
complication rate
12
suboccipital craniotomy/craniectomy
12
sitting
10
cases
9

Similar Publications

Pineal gland lesions pose a significant surgical challenge due to the deep-seated nature of the pineal gland, as well as the limited field of view, and the complex vascular anatomy. The mainstay of surgical treatment, when necessary, is always histopathological clarity and gross total resection (GTR). We evaluate the surgical outcomes for pineal gland lesions, shedding light on functional outcomes, histological findings, and surgical complications.

View Article and Find Full Text PDF

The present study aims to examine the effect of 4 h of continuous sitting on cerebral endothelial function, which is a crucial component of cerebral blood flow regulation. We hypothesized that 4 h of sitting may impair cerebral endothelial function similarly to how it affects lower limb vasculature. Thirteen young, healthy participants were instructed to remain seated for 4 h without moving their lower limbs.

View Article and Find Full Text PDF

We sought to clarify the interface pressure (IP) and its variation by applying Biflex16, a calibrated bandage, to the lower leg. In Study I, 50 participants applied a bandage to the lower leg of a single subject in two ways: first, with 50% overlap, while the calibration rectangle became a square (Application 1), and then with 50% overlap without intentional stretch (Application 2) which served as a control. In Study II, another 51 participants applied the bandage to their lower leg via Application 1.

View Article and Find Full Text PDF

: The purpose of this study was to quantify the impact of smartphone use while sitting on the toilet on the spinal flexion angles and the time effect. : Measurements of the spinal flexion angles in the sagittal plane were made by thirty participants while they sat on the toilet for 10 min, using a smartphone in either one, both, or neither hand. The individual's forehead, cervical, thoracic and lumbar spinal areas were each fitted with five different inertial motion sensors.

View Article and Find Full Text PDF

Transmissibility is used to assess dynamic responses of the occupant-seat system, and most studies have exclusively assessed the transmissibility from the floor to the cushion or the backrest surface with the human body. In this investigation, the vertical vibration transmitted from the floor to six specific locations both on the seat surface and the frame when the seat was fixed on three positions on the track was examined utilizing an SAE J826 manikin and 12 male adults (0.25 to 20 Hz) for a duration of 120 seconds at three vibration amplitudes.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!