Purpose: The purpose of this pilot study was to demonstrate the applicability of time-resolved three-dimensional (3D) reconstructions from 3D digital subtraction angiography (DSA) rotational angiography (RA) datasets (four-dimensional (4D) DSA) to provide a more detailed display of the architecture of intracranial vascular malformations.

Methods: The experimental reconstruction software was applied to the existing 3D DSA datasets obtained with Siemens Artis zee biplane neuroangiography equipment. We included 27 patients with clinical indications for 3DRA for preinterventional or preoperative evaluation of intracranial dural arteriovenous fistulas (dAVFs, n=8) or arteriovenous malformations (AVMs, n=19). A modified DSA acquisition protocol covering an extended rotation angle of the C-arm of 260° during a scan time of 12 s was used. 4D volumes were displayed with up to 30 frames/s in a transparent volume rendering (VRT) mode and time-resolved multiplanar reconstructions (MPRs). Arterial feeders, fistulous points, or the shunt zone within the AVM nidus and venous drainage patterns as well as associated aneurysms were assessed after definition of a standardized evaluation procedure by consensus of two reviewers in comparison with 2D DSA and conventional 3D reconstructions.

Results: In all cases calculation of 4D reconstructions were technically feasible and evaluable. In two cases image quality was slightly compromised by movement artifacts. Compared with standard DSA projection images and 3D reconstructions, 4D VRTs and MPRs were rated significantly superior to define a proper projection and display of the shunt zone. In 12 out of 27 cases 4D reconstructions showed details of the angioarchitecture at the fistulous point or the nidus better than the other modalities and came close to the quality of superselective angiography. The efficacy of 3D and 4D applications was equal in the detection of pre- and intranidal aneurysms. The course of long arterial feeders and draining veins was difficult to assess on VRTs and MPRs. Especially for dAVFs, 2D DSA was clearly superior in identifying meningeal feeders. For detecting smaller vessels and for distinction between angiographic phases, 2D DSA is still considered to be superior to 4D imaging. Venous drainage was slightly better displayed in 4D reconstructions.

Conclusions: Time-resolved 3DRA with 4D VRTs and MPRs is technically feasible and provides a detailed display of the angioarchitecture at the fistulous point or the nidus. Visualization of all angiographic features demands additional post-processing. Further standardization of evaluation tools and studies with blinded independent reviewers are necessary before the new technique can replace conventional neuroangiographic approaches.

Download full-text PDF

Source
http://dx.doi.org/10.1136/neurintsurg-2016-012462DOI Listing

Publication Analysis

Top Keywords

vrts mprs
12
rotational angiography
8
intracranial vascular
8
dsa
8
detailed display
8
arterial feeders
8
shunt zone
8
venous drainage
8
technically feasible
8
angioarchitecture fistulous
8

Similar Publications

Purpose: The purpose of this pilot study was to demonstrate the applicability of time-resolved three-dimensional (3D) reconstructions from 3D digital subtraction angiography (DSA) rotational angiography (RA) datasets (four-dimensional (4D) DSA) to provide a more detailed display of the architecture of intracranial vascular malformations.

Methods: The experimental reconstruction software was applied to the existing 3D DSA datasets obtained with Siemens Artis zee biplane neuroangiography equipment. We included 27 patients with clinical indications for 3DRA for preinterventional or preoperative evaluation of intracranial dural arteriovenous fistulas (dAVFs, n=8) or arteriovenous malformations (AVMs, n=19).

View Article and Find Full Text PDF

Purpose: To retrospectively evaluate the diagnostic accuracy of multidetector computed tomography (CT) coronary angiography for detection of hemodynamically significant (>or=50%) stenoses by using various image postprocessing methods, with conventional coronary angiography as the reference standard.

Materials And Methods: The analysis used data from previous studies, use of which had been approved by the Institutional Review Board. Sixteen-section multidetector CT data sets for 40 patients (30 men, 10 women; mean age 56 years +/- 8; mean heart rate, 61 beats per minute +/- 6) were evaluated.

View Article and Find Full Text PDF

Objectives: The aim of this study was to compare the image performance of silicon-based flat-panel-detector-based volumetric computed tomography (fpVCT) to multislice spiral computed tomography (MSCT) for the visualization and detail detectability of skeletal structures in rodents of different development stages.

Materials And Methods: Rodents of different development stages were imaged with fpVCT (GE prototype with circular gantry with two 1024 x 1024, 200-microm pixel size, amorphous silicon/Cesium lodid (Csl) flat-panel detector) and eight-slice MSCT (LightSpeed Ultra). Imaging parameters (80 kVp, 100 mA) and the position of the rodents were identical in both techniques.

View Article and Find Full Text PDF

Purpose: To evaluate the diagnostic accuracy of contrast-enhanced dose-reduced 16-slice multidetector-row CT (MDCT) in newborns and infants with fiberoptic bronchoscopically suspected vascular-induced tracheal stenosis.

Materials And Methods: 12 children (4 days to 3 years, 1.2 - 13.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!