AI Article Synopsis

  • The study investigates the safety of a one-incision technique for distal biceps repair, focusing on the distance from the posterior interosseous nerve (PIN) during the procedure.
  • Cadaver dissection revealed that a guidewire placement 5 mm more proximal from the radial tuberosity significantly increased the distance from the PIN, reducing potential nerve injury risks.
  • Clinical results from 10 patients showed good functional outcomes, with minimal loss in strength and range of motion, indicating this modified technique is both effective and safe.

Article Abstract

Background: The purpose of this study is to determine the safety of a one-incision technique for distal biceps repair with modified repair entry point in regards to the distance from the posterior interosseous nerve (PIN). Secondly, we present the clinical results of patients having undergone this procedure.

Methods: Ten cadaveric specimens were dissected to reveal the radial tuberosity. Two 1.6-mm guidewires were inserted into the radial tuberosity, one centrally, and one 5-mm more proximal. Both guidewires penetrated the dorsal cortex, and posterior dissection revealed their exit points. The distance from the PIN and each wire was determined using a vernier calliper. The functional outcomes of 10 patients' post repair were reviewed. Performance was determined using strength and range of motion (ROM) measurements. Functional impairment was assessed using the disability of the arm, shoulder and hand outcome measure (DASH score). The uninjured side was used as a control.

Results: The mean distance from the centre of the radial tuberosity to the PIN was 7.33 mm with a centrally placed wire, compared with 10.92 mm when measuring from the proximal guidewire (P < 0.05). Supination and flexion strengths were 83 and 90% of the uninjured side, respectively. There was a mean of 1.5° loss of flexion and 0° loss of extension. Loss of pronation and supination ROM were 0.5° and 4.5° on average, respectively. Average DASH score was 6.3.

Conclusion: We recommend a 5-mm more proximal entry point for insertion of the guidewire during distal biceps repair. This poses less risk to the PIN without significant functional impairment. Our outcomes are comparable with those reported in the literature.

Download full-text PDF

Source
http://dx.doi.org/10.1111/ans.13684DOI Listing

Publication Analysis

Top Keywords

distal biceps
12
biceps repair
12
entry point
12
radial tuberosity
12
repair modified
8
5-mm proximal
8
functional impairment
8
dash score
8
uninjured side
8
repair
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!