The effects of magnetic resonance (MR) pulse sequences and timing parameters on tumor-liver contrast were studied in an animal model of metastatic liver cancer. Six spin-echo (SE), three inversion-recovery (IR), and four gradient-echo (GRE) sequences were evaluated at 0.6 T before and after injection of super-paramagnetic iron oxide. GRE techniques, irrespective of echo time and flip angle, showed the greatest change in signal intensity (enhancement) of the liver after administration of iron oxide. Single-acquisition GRE sequences (16 seconds) matched the contrast-to-noise ratio (C/N) performance of the most effective 6.4-minute SE sequences. Multiexcitation GRE sequences showed tumor-liver C/Ns per unit time that were significantly (P less than .05) higher than those achieved with SE and IR sequences. GRE sequences, which recruit intravoxel dephasing as an additional source of transverse relaxation enhancement (T2*), show a higher C/N per unit time and in this respect seem superior to SE and IR sequences for MR imaging with superparamagnetic iron oxide.

Download full-text PDF

Source
http://dx.doi.org/10.1148/radiology.172.2.2748820DOI Listing

Publication Analysis

Top Keywords

gre sequences
16
iron oxide
12
superparamagnetic iron
8
liver cancer
8
sequences
8
unit time
8
gre
5
iron oxide-enhanced
4
oxide-enhanced imaging
4
imaging pulse
4

Similar Publications

Cerebral microbleeds (CMB) represent a feature of cerebral small vessel disease (cSVD), a prominent vascular contributor to age-related cognitive decline, dementia, and stroke. They are visible as spherical hypointense signals on T2*- or susceptibility-weighted magnetic resonance imaging (MRI) sequences. An increasing number of automated CMB detection methods being proposed are based on supervised deep learning (DL).

View Article and Find Full Text PDF

Comparing CT-like bone images based on FRACTURE MR with CT in pediatric congenital vertebral anomalies.

AJNR Am J Neuroradiol

December 2024

From the Department of Radiology (H.N.M., F.B.G.), Bai Jerbai Wadia Hospital for Children, Mumbai, Maharashtra, India.

Background And Purpose: Congenital vertebral anomalies are commonly associated with underlying spinal cord anomaly which necessitates imaging both the spinal cord and the bony vertebral column to understand the extent of the deformity better. While MRI is the gold standard for spinal cord imaging, it does not provide CT-like bone details. Many MR bone imaging techniques have been tested in various adult spine conditions in the past decade but not much has been described on their reliability in pediatric spine.

View Article and Find Full Text PDF

Enhanced Reader Confidence and Differentiation of Calcification from Cerebral Microbleed Diagnosis Using QSM Relative to SWI.

Clin Neuroradiol

December 2024

Department of Radiology, Beth Israel Deaconess Medical Center, Harvard Medical School, 1 Deaconess Road, Rosenberg B90A, 02215, Boston, MA, USA.

Purpose: Accurate detection of cerebral microbleeds (CMBs) is important for detection of multiple conditions. However, CMBs can be challenging to identify on MR images, especially for distinguishing CMBs from the mimic of calcification. We performed a comparative reader study to assess the diagnostic performance of two primary MR sequences for differentiating CMBs from calcification.

View Article and Find Full Text PDF

Objective: Investigate the association between the relative tumor enhancement (RTE) of gadoxetic acid across various MRI phases and immunohistochemical (IHC) features in patients with liver metastases (LM) from colorectal cancer (CRC), breast cancer (BC), and pancreatic cancer (PC).

Methods: A retrospective analysis was conducted on 68 patients with LM who underwent 1.5-T MRI scans.

View Article and Find Full Text PDF

Introduction: Magnetic resonance imaging (MRI) is both a crucial clinical and research tool for patients with deep brain stimulation (DBS) devices. However, safety concerns predominantly related to device heating have limited such imaging. Rigorous safety testing has demonstrated that scanning outside of vendor guidelines may be both safe and feasible, unlocking unique opportunities for advanced imaging in this patient population.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!