Tip-scanning high-speed atomic force microscopes (HS-AFMs) have several advantages over their sample-scanning counterparts. Firstly, they can be used on samples of almost arbitrary size since the high imaging bandwidth of the system is immune to the added mass of the sample and its holder. Depending on their layouts, they also enable the use of several tip-scanning HS-AFMs in combination. However, the need for tracking the cantilever with the readout laser makes designing tip-scanning HS-AFMs difficult. This often results in a reduced resonance frequency of the HS-AFM scanner, or a complex and large set of precision flexures. Here, we present a compact, simple HS-AFM designed for integrating the self-sensing cantilever into the tip-scanning configuration, so that the difficulty of tracking small cantilever by laser beam is avoided. The position of cantilever is placed to the end of whole structure, hence making the optical viewing of the cantilever possible. As the core component of proposed system, a high bandwidth tripod scanner is designed, with a scan size of 5.8 µm × 5.8 µm and a vertical travel range of 5.9 µm. The hysteresis of the piezoactuators in X- and Y-axes are linearized using input shaping technique. To reduce in-plane crosstalk and vibration-related dynamics, we implement both filters and compensators on a field programmable analog array. Based on these, images with 512 × 256 pixels are successfully obtained at scan rates up to 1024 lines/s, corresponding to a 4 mm/stip velocity. SCANNING 38:889-900, 2016. © 2016 Wiley Periodicals, Inc.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/sca.21338 | DOI Listing |
This paper presents a complete framework for capturing and processing hyperspectral reflectance images of artworks in situ, using a hyperspectral line scanner. These capturing systems are commonly used in laboratory conditions synchronized with scanning stages specifically designed for planar surfaces. However, when the intended application domain does not allow for image capture in these controlled conditions, achieving useful spectral reflectance image data can be a very challenging task (due to uncontrolled illumination, high-dynamic range (HDR) conditions in the scene, and the influence of chromatic aberration on the image quality, among other factors).
View Article and Find Full Text PDFForensic Sci Int
August 2018
The National Geospatial-Intelligence Agency, United States. Electronic address:
Unmarked graves are difficult to locate once the ground surface no longer shows visible evidence of disturbance, posing significant challenges to missing person investigations. This research evaluates the use of terrestrial LIDAR point data for measuring localized elevation change at human grave surfaces. Three differently sized human graves, one control-pit, and surrounding undisturbed ground, were scanned four times between February 2013 and November 2014 using a tripod-mounted terrestrial laser scanner.
View Article and Find Full Text PDFInterface Focus
April 2018
School of Humanities, Religion and Philosophy, York St John University, York YO31 9EX, UK.
The Salford Advanced Laser Canopy Analyser (SALCA) is an experimental terrestrial laser scanner designed and built specifically to measure the structural and biophysical properties of forest canopies. SALCA is a pulsed dual-wavelength instrument with co-aligned laser beams recording backscattered energy at 1063 and 1545 nm; it records full-waveform data by sampling the backscattered energy at 1 GHz giving a range resolution of 150 mm. The finest angular sampling resolution is 1 mrad and around 9 million waveforms are recorded over a hemisphere above the tripod-mounted scanner in around 110 min.
View Article and Find Full Text PDFJ Craniofac Surg
January 2017
*Department of Medical Imaging, HangZhou Medical College, Hangzhou †Digital Medical Research Center, School of Basic Medical Sciences, Fudan University, Shanghai, China..
Objective: The purpose of this study was to investigate the feasibility of a surface-based registration method based on a low-cost, hand-held Sense three-dimensional (3D) scanner in image-guided neurosurgery system.
Methods: The scanner was calibrated prior and fixed on a tripod before registration. During registration, a part of the head surface was scanned at first and the spatial position of the adapter was recorded.
Scanning
November 2016
Laboratory for Bio and Nano Instrumentation, Interfaculty Institute of Bioengineering, École Polytechnique Fédérale de Lausanne, Lausanne, Switzerland.
Tip-scanning high-speed atomic force microscopes (HS-AFMs) have several advantages over their sample-scanning counterparts. Firstly, they can be used on samples of almost arbitrary size since the high imaging bandwidth of the system is immune to the added mass of the sample and its holder. Depending on their layouts, they also enable the use of several tip-scanning HS-AFMs in combination.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!