As a step toward the realization of neuroprosthetics for vision restoration, we follow an electrophysiological patch-clamp approach to study the fundamental photoelectrical stimulation mechanism of neuronal model cells by an organic semiconductor-electrolyte interface. Our photoactive layer consisting of an anilino-squaraine donor blended with a fullerene acceptor is supporting the growth of the neuronal model cell line (N2A cells) without an adhesion layer on it and is not impairing cell viability. The transient photocurrent signal upon illumination from the semiconductor-electrolyte layer is able to trigger a passive response of the neuronal cells under physiological conditions via a capacitive coupling mechanism. We study the dynamics of the capacitive transmembrane currents by patch-clamp recordings and compare them to the dynamics of the photocurrent signal and its spectral responsivity. Furthermore, we characterize the morphology of the semiconductor-electrolyte interface by atomic force microscopy and study the stability of the interface in dark and under illuminated conditions.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acs.langmuir.6b02085DOI Listing

Publication Analysis

Top Keywords

semiconductor-electrolyte interface
12
photoelectrical stimulation
8
neuronal cells
8
cells organic
8
organic semiconductor-electrolyte
8
neuronal model
8
photocurrent signal
8
neuronal
4
stimulation neuronal
4
cells
4

Similar Publications

Regulating Chlorine and Hydrogen Atom Transfer for Selective Photoelectrochemical C─C Coupling by Cu-coordination Effect at Semiconductor/Electrolyte Interfaces.

Adv Sci (Weinh)

December 2024

Key Laboratory of Photochemistry, CAS Research/Education Center for Excellence in Molecular Sciences, Institute of Chemistry, Chinese Academy of Sciences, Beijing, 100190, P. R. China.

Semiconductor-based photoelectrochemical (PEC) organic transformations usually show radical characteristics, in which the reaction selectivity is often difficult to precisely control due to the nonselectivity of radicals. Accordingly, several simple organic reactions (e.g.

View Article and Find Full Text PDF

Ion sensors based on organic semiconductors acting as quasi-reference electrodes.

Proc Natl Acad Sci U S A

October 2024

Materials Innovation Research Center and Department of Advanced Materials Science, Graduate School of Frontier Sciences, The University of Tokyo, Kashiwa 277-8561, Chiba, Japan.

Thin-film devices that transduce the chemical activity of ions into electronic signals are essential components in various applications, including healthcare diagnostics and environmental monitoring. Combinations of organic semiconductors (OSCs) and ion-selective materials have been explored for developing solution-processable ion sensors. However, the necessity of reference electrodes (REs) and operational stability in ion-permeable OSCs have posed questions regarding whether reliable measurements with thin-film components are attainable with OSCs.

View Article and Find Full Text PDF

Herein, the FeS/TiO p-n heterojunction was first utilized as a photoelectrode for the PEC reduction of CO to selectively produce ethanol. The FeS/TiO photoelectrode was fabricated through electrochemical anodization, electrodeposition, and vulcanization methods. The impact of the FeS loading amount and applied bias on the PEC performance was investigated.

View Article and Find Full Text PDF

High-throughput testing of photoelectrochemical cells and materials under well-defined operating conditions can accelerate the discovery of new semiconducting materials, the characterization of the phenomena occurring at the semiconductor-electrolyte interface, or the understanding of the coupled multi-physics transport phenomena of a complete working cell. However, there have been few high-throughput systems capable of dealing with complete cells and applying variations in real-life operating conditions, like temperature or irradiance. Understanding the effects of the variations of these real-life operating conditions on the performance of photoelectrode materials requires reliable and reproducible measurements.

View Article and Find Full Text PDF

Proton-polarized states in DNA.

Biosystems

March 2024

University of Silesia, Faculty of Natural Sciences, Institute of Biology, Biotechnology, and Environmental Protection, 40-032 Katowice, Poland.

We observed signatures of a phase transition in the double-stranded DNA fragment of known length and sequences using a non-invasive semiconductor-electrolyte interface technique and statistical physics methods. Observations revealed a coherence peak in the electromotive force and a significant decline in calculated dynamic entropy at a critical temperature and pH. This behavior may arise from the dynamic interaction of proton (H) pairs with opposite momentum and spin, carrying a charge q=2+ under critical conditions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!