Intradialytic hypertension during chronic haemodialysis and subclinical fluid overload assessed by bioimpedance spectroscopy.

Clin Kidney J

Department of Medicine, Division of General Medicine and Nephrology, Faculty of Medicine and Health Sciences , Stellenbosch University, and Tygerberg Academic Hospital, Francie van Zijl Drive, Parow Valley , Stellenbosch , Cape Town, South Africa.

Published: August 2016

Background: Intradialytic hypertension (IDH) increases morbidity and mortality. The prevalence in South Africa is unknown. The pathogenesis is unclear, but it has been suggested that IDH may be due to subclinical fluid overload. The objective of this study was to determine the prevalence of IDH and to evaluate its association with fluid overload using bioimpedance spectroscopy (BIS).

Methods: A cross-sectional study involving 190 chronic haemodialysis patients in the Western Cape province of South Africa was conducted between January 2013 and May 2014. IDH was defined as a >10 mmHg increase in systolic blood pressure in at least four of six prior consecutive haemodialysis sessions.

Results: The prevalence of IDH was 28.4% (n = 54). There was a trend towards pre-dialysis overhydration in the IDH group when compared with controls {2.6 L [95% confidence interval (CI) 1.7-3.4] versus 1.8 L [95% CI 1.4-2.1], respectively; P = 0.06} as measured by BIS, but no difference in mean ultrafiltration (UF) volume (2.4 versus 2.6 L; P = 0.30). A trend towards greater use of antihypertensive drugs was noted in the IDH group [2.5 drugs (95% CI 2.15-2.87) versus 2.1 (95% CI 1.82-2.30); P = 0.05]. More participants in the IDH group received calcium channel blockers (54 versus 36; P = 0.03).

Conclusions: The prevalence of IDH in our treatment centres is much higher than previously reported. Subclinical fluid overload may be a major contributing factor to the mechanism of this condition. The use of BIS identifies patients who may benefit from additional UF.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4957728PMC
http://dx.doi.org/10.1093/ckj/sfw052DOI Listing

Publication Analysis

Top Keywords

fluid overload
16
subclinical fluid
12
prevalence idh
12
idh group
12
idh
9
intradialytic hypertension
8
chronic haemodialysis
8
bioimpedance spectroscopy
8
south africa
8
hypertension chronic
4

Similar Publications

Monitoring fluid intake and output for congestive heart failure (CHF) patients is an essential tool to prevent fluid overload, a principal cause of hospital admissions. Addressing this, bladder volume measurement systems utilizing bioimpedance and electrical impedance tomography have been proposed, with limited exploration of continuous monitoring within a wearable design. Advancing this format, we developed a conductivity digital twin from radiological data, where we performed exhaustive simulations to optimize electrode sensitivity on an individual basis.

View Article and Find Full Text PDF

Background: Out-of-hospital cardiac arrest (OHCA) is a significant global health challenge with high incidence and low survival rates; this study aimed to predict mortality in these patients.

Methods: This 5-year retrospective chart review, conducted at the emergency departments (EDs) of two tertiary hospitals, systematically categorized, coded, and analyzed variables to assess mortality risk in OHCA patients.

Results: Of the 822 (36.

View Article and Find Full Text PDF

Background: Sepsis is a critical condition associated with high mortality rates that necessitates effective fluid resuscitation. Crystalloids are widely utilized; however, human albumin solutions have been attributed potential oncotic and anti-inflammatory benefits. Given the ongoing debate and the absence of definitive empirical evidence, expert opinions provide valuable insights into the contextual and practical aspects of fluid management.

View Article and Find Full Text PDF

Metabolically stable apelin analogs: development and functional role in water balance and cardiovascular function.

Clin Sci (Lond)

January 2025

Center for Interdisciplinary Research in Biology, College de France, Institut National de la Santé et de la Recherche Médicale, Paris, France.

Apelin, a (neuro) vasoactive peptide, plays a prominent role in controlling water balance and cardiovascular functions. Apelin and its receptor co-localize with vasopressin in magnocellular vasopressinergic neurons. Apelin receptors (Apelin-Rs) are also expressed in the collecting ducts of the kidney, where vasopressin type 2 receptors are also present.

View Article and Find Full Text PDF

Introduction: Fluid overload (FO), a state of pathologic positive cumulative fluid balance (CFB), is common in Pediatric Intensive Care Units (PICU) and associated with morbidity and mortality. Because different PICUs may have unique needs, barriers, and limitations to accurately report fluid balance (FB) and reduce FO, understanding the drivers of positive FB is needed. We hypothesize CFB >5% and >10% is common within initial days of PICU admission, but that reasons for high %CFB will vary across sites, as will barriers to accurate FB recording and opportunities to improve FB recording and management.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!