A multi-wavelength, high contrast contact radiography system has been developed to characterize density variations in ultra-low density aerogel foams. These foams are used to generate a ramped pressure drive in materials strength experiments at the National Ignition Facility and require precision characterization in order to reduce errors in measurements. The system was used to characterize density variations in carbon and silicon based aerogels to ∼10.3% accuracy with ∼30 μm spatial resolution. The system description, performance, and measurement results collected using a 17.8 mg/cc carbon based JX-6 (C20H30) aerogel are discussed in this manuscript.

Download full-text PDF

Source
http://dx.doi.org/10.1063/1.4958826DOI Listing

Publication Analysis

Top Keywords

contact radiography
8
radiography system
8
aerogel foams
8
characterize density
8
density variations
8
multi-wavelength high-contrast
4
high-contrast contact
4
system
4
system study
4
study low-density
4

Similar Publications

Case: A 75-year-old woman underwent cruciate retaining total knee arthroplasty (TKA) for osteonecrosis of the knee, converted from unicompartmental arthroplasty due to an intraoperative medial tibial plateau fracture. Four years later, she experienced persistent knee pain. Computed tomography revealed tibial malalignments in 2 planes.

View Article and Find Full Text PDF

Evaluation of radiation therapy on grafted and non-grafted defects: an experimental rat model.

J Appl Oral Sci

January 2025

Universidade Federal de Uberlândia, Faculdade de Odontologia, Departamento de Periodontia e Implantodontia, Uberlândia, Brasil.

Objective: This study aimed to assess the effects of a single-dose radiation therapy (15 Gy) on grafted and non-grafted defects, bone microarchitecture, and collagen maturity.

Methodology: Bone defects were surgically created in rat femurs. The right femur defect was filled with blood clot (group "Clot") and the left femur defect by deproteinized bovine bone mineral graft (group "Xenograft").

View Article and Find Full Text PDF

Identifying a Reliable Intra-articular Landmark to Avoid Vascular Injury During Transacetabular Screw Fixation: A 3D Computed Tomography Study.

J Am Acad Orthop Surg

February 2025

From the Department of Orthopaedic Surgery, Keck Medical Center of the University of Southern California, Los Angeles, CA (Ihn, Chung, Lovro, Patterson, Christ, and Heckmann), the Department of Orthopaedic Surgery, Mayo Clinic, Rochester, MN (Chen), the Department of Orthopaedic Surgery, University of Pittsburgh, Pittsburgh, PA (Tucker), and the Department of Radiology, Keck Medical Center of the University of Southern California, Los Angeles, CA (White, and Hwang).

Introduction: Vascular injury during acetabular screw fixation is a life-threatening complication of total hip arthroplasty. This study uses three-dimensional computed tomography to (1) measure absolute distance from the external iliac artery (EIA) to the acetabulum, (2) determine available bone stock along the EIA path, and (3) create a novel acetabular vascular risk map.

Methods: A retrospective radiographic study was conducted using three-dimensional CT.

View Article and Find Full Text PDF

Purpose: Previous studies reported that anterior knee pain (AKP) occurs with an incidence of 32% after opening-wedge high tibial osteotomy (OWHTO). However, the biomechanical effects of this procedure on patellofemoral joints (PFJs) remain unclear. We aimed to quantify the changes in the kinematics and cartilage conditions of the PFJ during stair climbing before and after OWHTO.

View Article and Find Full Text PDF

For the purpose of assessing image quality and calculating patient X-ray dosage in radiology, computed tomography (CT), fluoroscopy, mammography, and other fields, it is necessary to have prior knowledge of the X-ray energy spectrum. The main components of an X-ray tube are an electron filament, also known as the cathode, and an anode, which is often made of tungsten or rubidium and angled at a certain angle. At the point where the electrons generated by the cathode and the anode make contact, a spectrum of X-rays with energies spanning from zero to the maximum energy value of the released electrons is created.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!