Although controlled procedures for the determination of carbonaceous fractions are of importance for any air quality measurements, currently no reference method for elemental carbon (EC) and organic carbon (OC) analysis is established yet in Europe. The implementation of the different thermal evolution protocols available in the literature, differing in temperature and duration of the heating ramps, affects the results and can result in a wide variation of EC and OC values. In this study three different protocols for thermal-optical-transmittance analysis of EC and OC were compared, namely He-870 (a variation of the NIOSH protocol), He-550 (a proxy of the IMPROVE protocol), and EUSAAR_2. Measurements were carried out on PM2.5 samples collected on Quartz fibre filters in three sites of different typology: urban background and urban traffic in Florence (Italy) and regional background in Livorno (Italy). The samples were analysed before and after a washing procedure to remove possible water-soluble organic compounds (WSOC), which may enhance the charring process, complicating the EC quantification. This study evidenced a very good agreement for TC measurement (at 2-3% level) and some discrepancies in EC measurement (up to 40%), as expected. WSOC and Pyrolitic Carbon (PyC) present a good correlation, independently of site typology, demonstrating that water soluble compound can be responsible of charring mechanism during the He phase.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.scitotenv.2016.07.128 | DOI Listing |