A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Bioresorbable vascular scaffolds technology: current use and future developments. | LitMetric

Bioresorbable vascular scaffolds technology: current use and future developments.

Med Devices (Auckl)

Cardiology Department, Clinic Cardiovascular Institute, Hospital Clinic, August Pi and Sunyer Biomedical Research Institute (IDIBAPS), University of Barcelona, Barcelona, Spain.

Published: July 2016

Coronary bioresorbable vascular scaffolds are a new appealing therapeutic option in interventional cardiology. The most used and studied is currently the Absorb BVS™. Its backbone is made of poly-L-lactide and coated by a thin layer of poly-D,L-lactide, it releases everolimus and is fully degraded to H2O and CO2 in 2-3 years. Absorb BVS™ seems to offer several theoretical advantages over metallic stent, as it gives temporary mechanical support to vessel wall without permanently caging it. Therefore, long-term endothelial function and structure are not affected. A possible future surgical revascularization is not compromised. Natural vasomotion in response to external stimuli is also recovered. Several observational and randomized trials have been published about BVS clinical outcomes. The main aim of this review is to carry out a systematic analysis about Absorb BVS™ studies, evaluating also the technical improvements of the Absorb GT1 BVS™.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4946828PMC
http://dx.doi.org/10.2147/MDER.S90461DOI Listing

Publication Analysis

Top Keywords

absorb bvs™
12
bioresorbable vascular
8
vascular scaffolds
8
scaffolds technology
4
technology current
4
current future
4
future developments
4
developments coronary
4
coronary bioresorbable
4
scaffolds appealing
4

Similar Publications