Reliability and Validity of Cervical Range of Motion and Muscle Strength Testing.

J Strength Cond Res

1Department of Physical Therapy, Faculty of Medicine, University of British Columbia, Vancouver, British Columbia, Canada; and 2Department of Physical Therapy, Faculty of Medicine, University of Toronto, Toronto, Ontario, Canada.

Published: April 2017

Kubas, C, Chen, Y-W, Echeverri, S, McCann, S, Denhoed, M, Walker, C, Kennedy, C, and Reid, WD. Reliability and validity of cervical range of motion and muscle strength testing. J Strength Cond Res 31(4): 1087-1096, 2017-Cervical range of motion (ROM) and strength are fundamental measures to assess treatment effectiveness. The JTECH wireless devices provide versatile means of quantifying these measurements. The purpose of this study was to determine intrarater and interrater reliabilities and concurrent validity of the JTECH wireless dual inclinometer and handheld dynamometer. This study included 20 healthy subjects (mean age = 28.7 ± 7.8 years). The directions of ROM movement measured were cervical flexion, extension, lateral flexion, and rotation. Isometric strength was measured for flexion, extension, and lateral flexion. Two testers measured cervical ROM and isometric strength for each subject using the JTECH devices during 2 or 3 sessions to determine reliability. The same ROM and muscle strength movements were measured using the CROM3 and MicroFET2, respectively, to assess concurrent validity. Reliability and validity were analyzed using intraclass correlation coefficient (ICC), along with SEM and minimal detectable change. The results of this study showed that the intrarater reliability of the JTECH inclinometer and dynamometer was moderate to excellent (ICCs (3,1) = 0.53-0.90 and 0.74-0.91, respectively). The interrater reliability of the JTECH inclinometer was moderate to excellent (ICCs (2,3) = 0.69-0.89), whereas the JTECH dynamometer showed excellent interrater reliability (ICCs (2,3) = 0.84-0.88). The JTECH inclinometer and dynamometer showed moderate to excellent concurrent validity (ICCs (3,2) = 0.65-0.91 and 0.91-0.96, respectively). With the ease of use, portability, and ability to record multiple measurements without stopping, these devices can be applied to clinical and research settings.

Download full-text PDF

Source
http://dx.doi.org/10.1519/JSC.0000000000001578DOI Listing

Publication Analysis

Top Keywords

reliability validity
12
range motion
12
muscle strength
12
concurrent validity
12
jtech inclinometer
12
moderate excellent
12
validity cervical
8
cervical range
8
motion muscle
8
strength testing
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!