A moveable lens is used for determining amplitude and phase on the object plane. The extended fractional Fourier transform is introduced to address the single lens imaging. We put forward a fast algorithm for the transform by convolution. Combined with parallel iterative phase retrieval algorithm, it is applied to reconstruct the complex amplitude of the object. Compared with inline holography, the implementation of our method is simple and easy. Without the oversampling operation, the computational load is less. Also the proposed method has a superiority of accuracy over the direct focusing measurement for the imaging of small size objects.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.24.016520DOI Listing

Publication Analysis

Top Keywords

coherent diffraction
4
diffraction imaging
4
imaging moving
4
moving lens
4
lens moveable
4
moveable lens
4
lens determining
4
determining amplitude
4
amplitude phase
4
phase object
4

Similar Publications

Coherent lensless imaging usually suffers from coherent noise and twin-image artifacts. In the terahertz (THz) range, where wavelengths are 2 to 4 orders of magnitude longer than those in the visible spectrum, the coherent noise manifests primarily as parasitic interference fringes and edge diffraction, rather than speckle noise. In this work, to suppress the Fabry-Pérot (F-P) interference fringes, we propose a novel method, which involves the averaging over multiple diffraction patterns that are acquired at equal intervals within a sample's half-wavelength axial shift.

View Article and Find Full Text PDF

Partially coherent beams are renowned for their inherent resilience against environmental perturbations. However, traditional versions are prone to distortion due to light diffraction, which presents significant challenges for related applications such as information transfer. In this paper, we theoretically and experimentally construct a non-diffraction, partially coherent Pearcey beam.

View Article and Find Full Text PDF

This paper introduces an interferometer for single-shot areal quantitative phase imaging at two wavelengths simultaneously, suitable for use with low coherence sources. It operates in reflection geometry with on-axis illumination, so that it can be conveniently applied to surface texture measurements. The system consists of two identical 4f systems forming the reference and sample arm.

View Article and Find Full Text PDF

We demonstrate PaCMAN, a ptychography algorithm that can reconstruct high quality images with broadband illumination sources while being robust to shot, detector, and parasitic noise. We extend prior monochromatization work to improve accuracy, especially for discrete spectra, and also demonstrate how PaCMAN can be converted into Ms. PaCMAN, a multi-spectral variant that outperforms multi-spectral ePIE.

View Article and Find Full Text PDF

This study investigates (EIG) in a nanohybrid configuration involving a semiconductor quantum dot (SQD) and a core-shell bimetallic nanoparticle coated with graphene. The goal is to optimize interactions between plasmons and excitons. This is achieved by utilizing nanoparticles covered with graphene, which enhances control over surface plasmons.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!