Two-dimensional (2D) materials can uniquely span the physical dimensions of a surrounding composite matrix in the limit of maximum reinforcement. However, the alignment and assembly of continuous 2D components at high volume fraction remain challenging. We use a stacking and folding method to generate aligned graphene/polycarbonate composites with as many as 320 parallel layers spanning 0.032 to 0.11 millimeters in thickness that significantly increases the effective elastic modulus and strength at exceptionally low volume fractions of only 0.082%. An analogous transverse shear scrolling method generates Archimedean spiral fibers that demonstrate exotic, telescoping elongation at break of 110%, or 30 times greater than Kevlar. Both composites retain anisotropic electrical conduction along the graphene planar axis and transparency. These composites promise substantial mechanical reinforcement, electrical, and optical properties at highly reduced volume fraction.

Download full-text PDF

Source
http://dx.doi.org/10.1126/science.aaf4362DOI Listing

Publication Analysis

Top Keywords

volume fraction
8
layered scrolled
4
scrolled nanocomposites
4
nanocomposites aligned
4
aligned semi-infinite
4
semi-infinite graphene
4
graphene inclusions
4
inclusions platelet
4
platelet limit
4
limit two-dimensional
4

Similar Publications

The dispersion of cellulose nanocrystals (CNCs) in suspensions determines the quality of the CNC-reinforced composites. Before being mixed into the composite matrix, stable suspensions must maintain a well-dispersed state, requiring proper design strategies to prevent agglomeration and precipitation. Considering the volume fraction, aspect ratio, and zeta potential, this paper proposes a coarse-grained model to simulate CNC clustering and an experimental program to observe accelerated precipitation of CNCs.

View Article and Find Full Text PDF

Objective: Cardiac computed tomography (CT) helps screen coronary artery stenosis in cases with dilated cardiomyopathy (DCM). Extracellular volume fraction (ECV) analysis has recently been eligible for CT.

Method: We evaluated the impact of ECV on the CT to predict the prognosis in DCM patients with heart failure with reduced ejection fraction (HFrEF).

View Article and Find Full Text PDF

Background: Coronary heart disease the most prevalent form of cardiovascular disease, results from the blockage of blood flow through arteries. The Myocardial Perfusion Scan (MPS) is considered a non-invasive method to assess the heart condition and provides valuable information, such as End Diastolic Volume (EDV), End Systolic Volume (ESV), Ejection Fraction (EF), Lung to Heart Ratio (LHR), and Transient Ischemic Dilatation (TID).

Objective: This study aimed to investigate changes in gated heart scan parameters to diagnose patients, who are candidates for heart surgery.

View Article and Find Full Text PDF

Where the microbes aren't.

FEMS Microbiol Rev

December 2024

UK Centre for Astrobiology, School of Physics and Astronomy, University of Edinburgh, Edinburgh, EH93JZ, UK.

Although a large fraction of Earth's volume and most places beyond the planet lack life because physical and chemical conditions are too extreme, intriguing scientific questions are raised in many environments within or at the edges of life's niche space in which active life is absent. This review explores the environments in which active microorganisms do not occur. Within the known niche space for life, uninhabited, but habitable physical spaces potentially offer opportunities for hypothesis testing, such as using them as negative control environments to investigate the influence of life on planetary processes.

View Article and Find Full Text PDF

Multiparametric cardiovascular magnetic resonance is associated with outcomes in pediatric heart transplant recipients.

J Cardiovasc Magn Reson

December 2024

Division of Cardiology, Department of Pediatrics, Ann & Robert H. Lurie Children's Hospital of Chicago, Northwestern University Feinberg School of Medicine, Chicago, IL, USA, E Chicago Ave, Box 21. Chicago, IL, 60611.

Background: Multiparametric cardiovascular magnetic resonance (CMR) has an emerging role in non-invasive surveillance of pediatric heart transplant recipients (PHTR). Higher myocardial T2, higher extracellular volume fraction (ECV), and late gadolinium enhancement (LGE) have been associated with adverse clinical outcomes in adult heart transplant recipients. This study's purpose was to investigate the prognostic value of CMR-derived T1- and T2-mapping, ECV, and LGE for clinical outcomes in PHTR.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!