Probe-free and sensitive detection of diarrhea-causing pathogens using RT-PCR combined high resolution melting analysis.

Biologicals

State Key Laboratory of Diarrhea Disease Detection, Zhuhai International Travel Healthcare Center, Zhuhai Entry-Exit Inspection and Quarantine Bureau, Zhuhai, Guangdong, China.

Published: September 2016

Rapid and sensitive diagnostic methods are needed to help physicians make faster and better treatment decision for patients suffered from diarrhea. In the present study, a probe-free and sensitive RT-PCR combined high resolution melting analysis (HRMA) assay was established successfully for the detection of four major diarrhea-causing pathogens. The lower limit of detection of the assay were 10(0), 10(2), 10(0) and 10(3) copies/reaction for rotaviruses group A, astroviruses serotype 1, noroviruses genogroup II, and sapoviruses genegroup I, respectively, which were 1000-fold, 10-fold, 1000-fold and 10-fold more sensitive than conventional RT-PCR assay developed in parallel and comparable to or higher than commercially available real-time RT-PCR assay. Blinded sample evaluation showed that the assay was 100% concordant to both conventional RT-PCR and commercial real-time RT-PCR, indicating high reliability of the new assay. Therefore, the assay could provide a valuable platform for the probe-free and sensitive diagnosis of these pathogens.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.biologicals.2016.06.012DOI Listing

Publication Analysis

Top Keywords

probe-free sensitive
12
diarrhea-causing pathogens
8
rt-pcr combined
8
combined high
8
high resolution
8
resolution melting
8
melting analysis
8
1000-fold 10-fold
8
conventional rt-pcr
8
rt-pcr assay
8

Similar Publications

Laser-ablated graphene electrodes modified with redox melanin-like film for redox capacitive sensing via the scavenging of nitrite ions.

Food Chem

December 2024

Sensors and Biosensors Group, Analytical Chemistry and Electrochemistry Lab (LR99ES15), University of Tunis El Manar, Tunis El Manar, 2092 Tunis, Tunisia. Electronic address:

Improper use and harmful effects of nitrite ions pose a significant risk to human health. To address this concern, the use of carbon-based materials for electrochemical sensing is regarded as one of the most promising detection tools for ensuring the quality of drinking water and food products. In this context, we developed laser-ablated graphene electrodes (LAGEs) by direct laser scribing on a polyimide substrate, which were subsequently modified by electrochemical deposition of a redox-active melanin-like film (MeLF/LAGEs).

View Article and Find Full Text PDF

Phosphorylated Tau proteins are promising biomarkers for the diagnosis and prognosis of Alzheimer's disease. This study presents a novel voltametric sensor using a vanadium MXene polydopamine (VPDA) redox active composite and a Tau-441-specific polyaniline molecularly imprinted polymer (PANI MIP) for the sensitive detection of Tau-441 in interstitial fluid (ISF) and plasma. The VPDA/PANI MIP sensor demonstrates a broad detection range of 5 fg/mL to 5 ng/mL (122 aM/L to 122 pM/L) in ISF without the use of redox mediators, with a lower limit of detection (LOD) of 2.

View Article and Find Full Text PDF

Raman spectroscopy in the study of amyloid formation and phase separation.

Biochem Soc Trans

June 2024

Laboratory of Protein Conformation and Dynamics, Biochemistry and Biophysics Center, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, MD, U.S.A.

Neurodegenerative diseases, such as Alzheimer's and Parkinson's, share a common pathological feature of amyloid structure accumulation. However, the structure-function relationship between these well-ordered, β-sheet-rich, filamentous protein deposits and disease etiology remains to be defined. Recently, an emerging hypothesis has linked phase separation, a process involved in the formation of protein condensates, to amyloid formation, suggesting that liquid protein droplets serve as loci for amyloid initiation.

View Article and Find Full Text PDF

Loop-mediated isothermal amplification (LAMP) is a rapid, sensitive, and cost-effective method for developing point-of-care nucleic acid testing due to its isothermal nature. Yet, LAMP can suffer from the issue of false positives, which can compromise the specificity of the results. LAMP false positives typically arise due to contamination, nonspecific amplification, and nonspecific signal reporting (intercalating dyes, colorimetric, turbidity, etc.

View Article and Find Full Text PDF

Redox probe-free electrochemical immunosensor utilizing electropolymerized melamine on reduced graphene oxide for the point-of-care diagnosis of gastric cancer.

Talanta

April 2024

Department of Chemistry, Khalifa University of Science and Technology, Abu Dhabi, P.O. Box 127788, United Arab Emirates; Advanced Materials Chemistry Center (AMCC), Khalifa University of Science and Technology, Abu Dhabi, P.O. Box 127788, United Arab Emirates. Electronic address:

Pepsinogen I (PG I) is a biomarker that plays a crucial role in the diagnosis of gastric cancer. The development of biosensor to monitor PG I overexpression in serum is crucial for early gastric cancer diagnosis, offering a less invasive alternative to the costly and uncomfortable gastroscopy procedure. This study presents a cost-efficient, scalable and disposable label-free biosensing strategy for detecting PG I, utilizing a redox-active polymelamine electrodeposited on a reduced graphene oxide screen-printed electrode surface (PM-rGO/SPE).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!