A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Contrast-enhanced ultrasound (CEUS) in assessing early response among patients with invasive breast cancer undergoing neoadjuvant chemotherapy. | LitMetric

Background One of the big challenges in onco-radiology is to find a reliable imaging method that may predict early response during the first cycles of any neoadjuvant chemotherapy. Purpose To evaluate the use of real-time harmonic contrast-enhanced ultrasound (CEUS) in predicting early response in breast cancer tumors under neoadjuvant chemotherapy (NAC) treatment. Material and Methods Nineteen consecutive patients with invasive breast cancer were evaluated with a bolus dose of 2.4 mL contrast agent using CEUS, before and after two cycles of epirubicin and docetaxel. The lognormal function was used for quantitative analysis of kinetic data to evaluate early response. Results There was statistically significant difference in time-to-peak ( t) between responders and non-responders (two sample t-test, P = 0.027) where t was significantly longer at the week 5 than at the baseline scan among responders when compared to non-responders. Conclusion In-flow of intravascular contrast agent in tumors is significantly slower in responders at real-time harmonic CEUS, and might be effectively used for the evaluation of early response to chemotherapy in invasive breast cancer. However, further investigations in a larger and more heterogeneous population should be performed to corroborate the reliability of the method.

Download full-text PDF

Source
http://dx.doi.org/10.1177/0284185116658322DOI Listing

Publication Analysis

Top Keywords

early response
20
breast cancer
16
invasive breast
12
neoadjuvant chemotherapy
12
contrast-enhanced ultrasound
8
ultrasound ceus
8
patients invasive
8
real-time harmonic
8
contrast agent
8
early
5