Aims: Repeated angiograms to achieve an exactly orthogonal visualization of the aortic valve plane can substantially contribute to the total contrast amount required for transcatheter aortic valve implantation (TAVI). We investigated whether pre-procedural identification of an optimal fluoroscopic projection by cardiac computed tomography (CT) can significantly reduce the amount of a procedure-related contrast agent compared with angiographic determination of suitable angulations.
Methods And Results: Eighty consecutive patients (81 ± 5 years, 55% male) with symptomatic severe aortic valve stenosis and normal renal function who underwent cardiac CT prior to TAVI were prospectively randomized. In 40 patients, a CT-predicted suitable angulation was used for the first aortic angiogram (CT cohort); in the other 40 patients, the first aortogram was acquired at LAO 10°/cranial 10 (angiography cohort). Additional aortograms were performed if no satisfactory view of the aortic valve plane was obtained. The number of aortograms needed to achieve a satisfactory fluoroscopic projection (1.2 ± 0.6 vs. 3.2 ± 1.7; P < 0.001) and the total amount of contrast agent per TAVI procedure were significantly lower in the CT cohort (95 ± 21 vs. 125 ± 36 mL; P < 0.001). Incidence of acute kidney injury was not significantly different. There was no significant difference regarding radiation dose, time of procedure, degree of post-procedural aortic regurgitation, complications and 30-day mortality between the cohorts.
Conclusion: Pre-procedural identification of a suitable fluoroscopic projection by cardiac CT significantly reduces a procedural contrast agent volume required for TAVI.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1093/ehjci/jew144 | DOI Listing |
Int J Cardiovasc Imaging
January 2025
Cardiology Division, Montefiore Medical Center, Albert Einstein College of Medicine, 111 E 210st, Bronx, NY, USA.
Computed tomography (CT)-derived Epicardial Adipose Tissue (EAT) is linked to cardiovascular disease outcomes. However, its role in patients undergoing Transcatheter Aortic Valve Replacement (TAVR) and the interplay with aortic stenosis (AS) cardiac damage (CD) remains unexplored. We aim to investigate the relationship between EAT characteristics, AS CD, and all-cause mortality.
View Article and Find Full Text PDFHeart Lung Circ
January 2025
Edwards Lifesciences ANZ, Sydney, NSW, Australia.
Background: Untreated severe heart valve disease (HVD) is associated with premature mortality. Research shows low population awareness of when to seek assessment and low focus on cardiac auscultation by physicians in primary care settings. We studied contemporary public knowledge of HVD and assessment by their general practitioner (GP) in Australia.
View Article and Find Full Text PDFCan J Cardiol
January 2025
Division of Cardiac Surgery, Rady Faculty of Health Sciences, University of Manitoba, Winnipeg, MB. Electronic address:
The volume of transcatheter aortic valve implantation (TAVI) for treatment of isolated aortic stenosis has far surpassed surgical aortic valve replacement (SAVR). There has been a consequent increase in TAVI explantation, now the fastest growing cardiac surgical procedure. Transcatheter heart valve explantation can be technically complex, with higher perioperative morbidity and mortality than routine SAVR or valve-in-valve TAVI.
View Article and Find Full Text PDFJ Thorac Cardiovasc Surg
January 2025
Department of Surgery, Division of Vascular Surgery, University of Maryland School of Medicine.
Objective: We present our experience with endovascular Bentall procedure (Endo-Bentall) using a modular valve conduit (Endo-Bentall) in high-risk patients with aortic root pathologies.
Methods: The physician constructed Endo-Bentall device is composed of a self-expanding transcatheter aortic valve (TAVR), aortic endovascular stent graft (TEVAR), and two wire-reinforced fenestrations for coronary artery stenting. The TAVR valve is sutured into an appropriately sized TEVAR graft.
J Thorac Cardiovasc Surg
January 2025
University of Maryland School of Medicine, Division of Cardiothoracic Surgery. Electronic address:
Objective: Over 30% of patients presenting with acute type A aortic dissection (ATAAD) are considered high - risk or inoperable. This study aims to investigate the early and mid-term outcomes of complex endovascular aortic repair of aortic root, ascending aorta, and aortic arch among patients with ATAAD.
Methods: From January 2018 to January 2023, 29 patients who were considered high risk for open operation underwent endovascular aortic repair.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!