Establishment of an equine tetanus antitoxin reference standard for veterinary use in Japan.

Biologicals

National Veterinary Assay Laboratory, Ministry of Agriculture, Forestry and Fisheries, 1-15-1, Tokura, Kokubunji, Tokyo 185-8511, Japan.

Published: September 2016

AI Article Synopsis

  • A National Veterinary Assay Laboratory (NVAL) was established to create a reference standard for equine tetanus antitoxin, resulting in 115 quality-tested vials.
  • Three laboratories conducted potency assays on the candidate standard, yielding consistent results between 38 and 42 IU with no significant statistical issues.
  • The final assessment determined the antitoxin potency to be 40 units per 1-mL vial, with these vials officially distributed as the first reference standard for veterinary use in September 2015.

Article Abstract

To establish the first National Veterinary Assay Laboratory (NVAL) equine tetanus antitoxin reference standard for veterinary use, we manufactured vials of a candidate antitoxin. These were quality tested for moisture content, vacuum, colour, clarity, and the presence of foreign objects. Ultimately, 115 quality-controlled vials were prepared. To estimate the antitoxin potency of the candidate standard, three different laboratories conducted parallel line assays alongside the existing antitoxin standard. These potency estimates ranged from 38 to 42 IU. This activity was maintained for two years after manufacture, as compared with a fresh vial. No statistically significant non-linearity or non-parallelism of the regression lines was observed (p > 0.05). Statistical assessment of inter- and intra-laboratory variability revealed acceptable coefficients of variation of 3.2% and 2.4-3.1%, respectively. Based on these results, the potency of the potential reference standard was calculated at 40 units of antitoxin activity per 1-mL vial. Vials of this preparation were distributed for use as the first equine tetanus antitoxin reference standard for veterinary use in September 2015.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.biologicals.2016.06.008DOI Listing

Publication Analysis

Top Keywords

reference standard
16
equine tetanus
12
tetanus antitoxin
12
antitoxin reference
12
standard veterinary
12
antitoxin
7
standard
6
establishment equine
4
reference
4
veterinary
4

Similar Publications

Gold nanoparticles (AuNPs) and their biocompatible conjugates find wide use as transducers in (bio)sensors and as Nano-pharmaceutics. The study of the interaction between AuNPs and proteins in representative application media helps to better understand their intrinsic behaviors. A multi-environment, multi-parameter screening strategy is proposed based on asymmetric flow field flow fractionation (AF4)-multidetector.

View Article and Find Full Text PDF

Methods to prepare and characterize neutron helical waves carrying orbital angular momentum (OAM) were recently demonstrated at small-angle neutron scattering (SANS) facilities. These methods enable access to the neutron orbital degree of freedom which provides new avenues of exploration in fundamental science experiments as well as in material characterization applications. However, it remains a challenge to recover phase profiles from SANS measurements.

View Article and Find Full Text PDF

Introduction: Systemic lupus erythematosus (SLE) is an autoimmune disease characterized by an overactive immune response, particularly involving excessive production of type I interferons. This overproduction is driven by the phosphorylation of IRF7, a crucial factor in interferon gene activation. Current treatments for SLE are often not very effective and can have serious side effects.

View Article and Find Full Text PDF

In a slim-floor structural system, beams and slabs are placed at the same level, reducing the overall floor height and material usage in vertical structures, thereby improving economic efficiency. The use of slim-floor structures is common practice in Finnish construction where these structures are typically constructed using hollow-concrete slabs and welded steel box beams. However, in Finland, only a few buildings utilise cross-laminated timber (CLT) slabs in slim-floor structures, and none have incorporated the composite action between CLT and steel beams.

View Article and Find Full Text PDF

A new risk assessment model of venous thromboembolism by considering fuzzy population.

BMC Med Inform Decis Mak

December 2024

Department of Respiration, Peking Union Medical College Hospital, No.1, Shuaifuyuan, Dongcheng District, Beijing, 100730, China.

Background: Inpatients with high risk of venous thromboembolism (VTE) usually face serious threats to their health and economic conditions. Many studies using machine learning (ML) models to predict VTE risk overlook the impact of class-imbalance problem due to the low incidence rate of VTE, resulting in inferior and unstable model performance, which hinders their ability to replace the Padua model, a widely used linear weighted model in clinic. Our study aims to develop a new VTE risk assessment model suitable for Chinese medical inpatients.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!