Introduction: The two-port laparoscopic appendectomy technique (TPLA) lays between the conventional three-port trocar procedure and single-port laparoscopic appendectomy surgery. During TPLA, the appendix is suspended with stitches, resulting in perforation risk and difficulty in exploration.

Aim: We used a needle grasper in TPLA to hang and manipulate the appendix.

Material And Methods: Thirty-four patients (10 female, 24 male) who underwent TPLA between February 2015 and November 2015 were analyzed retrospectively for patient demographics, duration of operation, laparotomy or conventional laparoscopy necessity, drain use, complications, and hospital stay periods. The needle grasper was inserted at the right under the abdominal quadrant (McBurney point) without an incision to hang and manipulate the appendix.

Results: The mean age was 25.19 ±8.464 years; the mean body mass index (BMI) was 23.50 ±3.246 kg/m(2). ASA scores were 1 and 2. The operations were completed without any additional trocar in 34 patients. The mean operation time was 57.03 ±3.814 min. There were no intraoperative complications in any patients. Three patients required a drain; all were discharged after drain removal. Thirty-one patients were discharged on the 1(st) postoperative day; three patients with drains were discharged on the 2(nd) day. The mean hospital stay period was 1.18 ±0.535 days.

Conclusions: Using the needle grasper, the appendix was held and suspended and the mesoappendix was cauterized and skeletonized successfully in TPLA. Inserting a needle grasper into the abdominal cavity at the McBurney point to manipulate the appendix helps and does not leave a visible scar.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4945612PMC
http://dx.doi.org/10.5114/wiitm.2016.60504DOI Listing

Publication Analysis

Top Keywords

needle grasper
20
laparoscopic appendectomy
16
two-port laparoscopic
8
hang manipulate
8
hospital stay
8
mcburney point
8
three patients
8
patients
6
needle
5
grasper
5

Similar Publications

Study Objective: To determine the association of repeat polypectomy with patient and/or polyp characteristics, surgical setting, and type of hysteroscopic equipment.

Methods: Retrospective cohort study including all women who had undergone operative hysteroscopy for the removal of endometrial polyps between 1/2012-12/2022 in our division. Operative hysteroscopy with resection of endometrial polyps was performed using a bipolar loop resectoscope, miniaturized hysteroscopic instruments (bipolar needle, scissors, and graspers), or a tissue-removal device (from April 2021), with or without general anesthesia.

View Article and Find Full Text PDF

Achieving sufficient attachment of deep rotator cuff tissue to the footprint area on the greater tubercle of the humerus is essential for functional recovery, yet the optimal approach remains uncertain. We introduce a surgical technique for rotator cuff tear repair using a spinal needle to penetrate deep rotator cuff tissue under direct arthroscopic visualization. After trimming the torn edge, an arthroscope is inserted into the joint cavity through a posterior portal, and a hole is drilled into the humeral head cartilage margin using an upper approach, facilitating the implantation of an internal shoulder row nail.

View Article and Find Full Text PDF

The main method for arthroscopic repair of the subscapularis is repair with suture anchors. The surgeon generally establishes the anterior and anterolateral operation portals to complete anchor implantation and suture passing, respectively. The single-operation portal technique has been developed recently.

View Article and Find Full Text PDF

Current Issues in Reduced-Port Gastrectomy: A Comprehensive Review.

J Gastric Cancer

January 2024

Department of Surgery, Chung-Ang University Hospital, Chung-Ang University College of Medicine, Seoul, Korea.

Reduced-port gastrectomy (RPG) includes all procedures derived from various efforts to minimize surgical invasiveness, with single-incision laparoscopic gastrectomy (SILG) being the ultimate reduced-port technique. However, there are challenges related to its feasibility, oncological validity, training, and education. This review describes the current issues and challenges, as well as the future prospects of RPG for gastric cancer.

View Article and Find Full Text PDF

Minimally invasive spine surgery (MISS) is increasingly performed using endoscopic and microscopic visualization, and the captured video can be used for surgical education and development of predictive artificial intelligence (AI) models. Video datasets depicting adverse event management are also valuable, as predictive models not exposed to adverse events may exhibit poor performance when these occur. Given that no dedicated spine surgery video datasets for AI model development are publicly available, we introduce Simulated Outcomes for Durotomy Repair in Minimally Invasive Spine Surgery (SOSpine).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!