Radiation Protection in Radiology, Nuclear Medicine and Radio Oncology is of the utmost importance. Radioiodine therapy is a frequently used and effective method for the treatment of thyroid disease. Prior to each therapy the radioactivity of the [131I]-capsule must be determined to prevent misadministration. This leads to a significant radiation exposure to the staff. We describe an alternative method, allowing a considerable reduction of the radiation exposure. Two [131I]-capsules (A01 = 2818.5; A02 = 7355.0 MBq) were measured multiple times in their own delivery lead containers - that is to say, [131I]-capsules remain inside the containers during the measurements (shielded measurement) using a dose calibrator and a well-type and a thyroid uptake probe. The results of the shielded measurements were correlated linearly with the [131I]-capsules radioactivity to create calibration curves for the used devices. Additional radioactivity measurements of 50 [131I]-capsules of different radioactivities were done to validate the shielded measuring method. The personal skin dose rate (HP(0.07)) was determined using calibrated thermo luminescent dosimeters. The determination coefficients for the calibration curves were R2 > 0.9980 for all devices. The relative uncertainty of the shielded measurement was < 6.8%. At a distance of 10 cm from the unshielded capsule the HP(0.07) was 46.18 μSv/(GBq•s), and on the surface of the lead container containing the [131I]-capsule the HP(0.07) was 2.99 and 0.27 μSv/(GBq•s) for the two used container sizes. The calculated reduction of the effective dose by using the shielded measuring method was, depending on the used container size, 74.0% and 97.4%, compared to the measurement of the unshielded [131I]-capsule using a dose calibrator. The measured reduction of the effective radiation dose in the practice was 56.6% and 94.9 for size I and size II containers. The shielded [131I]-capsule measurement reduces the radiation exposure to the staff significantly and offers the same accuracy of the unshielded measurement in the same amount of time. In order to maintain the consistency of the measuring method, monthly tests have to be done by measuring a [131I]-capsule with known radioactivity.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5690049PMC
http://dx.doi.org/10.1120/jacmp.v17i4.5942DOI Listing

Publication Analysis

Top Keywords

radiation exposure
16
measuring method
12
effective method
8
radioiodine therapy
8
reduction radiation
8
exposure staff
8
shielded measurement
8
dose calibrator
8
calibration curves
8
shielded measuring
8

Similar Publications

Objective: The purpose of this study was to present a newly designed 3D-printed personalized model (3D PPM) of a radiofrequency needle guide with a maxillary fixation for gasserian ganglion (GG) puncture.

Methods: Implementation of 3D CT-guided radiofrequency therapy of the GG with and without use of 3D PPM was analyzed. The following parameters were assessed: radiation time, dose area product, air kerma reference point, pain severity during the puncture needle insertion, prosopalgia regression degree (according to visual analog scale) and the severity of facial numbness (according to the Barrow Neurological Institute scale) in the early postoperative period, and postpuncture complications.

View Article and Find Full Text PDF

Association of -607C/A (rs1946518) and -137G/C (rs187238) polymorphisms and immune response in radiation-exposed workers.

Int J Radiat Biol

January 2025

Research Center for Radioisotope, Radiopharmaceutical, and Biodosimetry Technology, Research Organization for Nuclear Energy, National Research and Innovation Agency, Serpong, Indonesia.

Purpose: Interleukin-18, transforming growth factor-β, and superoxide dismutase are important cytokines and antioxidants in protecting the body from damage caused by radiation exposure through an immune response mechanism. Genetic polymorphisms -607 C/A and -137 G/C are thought to affect the IL-18 cytokine in carrying out its function as a biomarker to indicate adverse conditions due to radiation. The purposes of this study were to investigate the association between 607 C/A and -137 G/C SNPs on the concentrations of IL-18, and to measure TGF-β and SOD activity in radiation workers and control group.

View Article and Find Full Text PDF

Background: Exposure to Ultraviolet radiation (UVR) is a major risk factor for skin cancer. Data about UVR risk knowledge and exposure behaviors in the Lebanese population are scarce.

Aim: To evaluate the association between UVR risks knowledge, attitudes, and behaviors among Lebanese university students in the aim of promoting primary prevention of skin cancer.

View Article and Find Full Text PDF

High-Specific Power Flexible Photovoltaics from Large-Area MoS for Space Applications.

ACS Appl Energy Mater

January 2025

Department of Physics and Engineering Physics, Tulane University, New Orleans, Louisiana 70118-5636, United States.

Two-dimensional (2D) transition metal dichalcogenides (TMDCs) such as MoS and WSe are excellent candidates for photovoltaic (PV) applications. Here, we present the modeling, fabrication, and characterization of large-area CVD-grown MoS-based flexible PV on an off-the-shelf, 3 μm-thick flexible colorless polyimide with polyimide encapsulation designed for space structures. The devices are characterized under 1 sun AM0 illumination and show a of 0.

View Article and Find Full Text PDF

Background: The consequence of non-compliance with patient radiation safety standards increases unnecessary radiation exposure with high chances of harmful biological effects. Radiographers are trained to prevent these harmful effects by enforcing radiation protection, which is achieved through proper techniques, equipment, shielding materials and beam collimation.

Aim: The study aimed to explore compliance with radiation protection by radiographers in Eswatini public health facilities (PHFs).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!