Utility of computed tomographic imaging of the cervical spine in trauma evaluation of ground-level fall.

J Trauma Acute Care Surg

From the Departments of Radiology and Imaging Sciences (M.D.B., J.W.A., M.U., C.A.H.), and Neurology (J.W.A.), School of Medicine (M.D.B., J.W.A., B.P.L., M.U., R.M.S., C.A.H.), Emory University, Atlanta, Georgia.

Published: August 2016

Background: Computed tomography (CT) of the cervical spine (C-spine) is routinely ordered for low-risk mechanisms of injury, including ground-level fall. Two commonly used clinical decision rules (CDRs) to guide C-spine imaging in trauma are the National Emergency X-Radiography Utilization Study (NEXUS) and the Canadian Cervical Spine Rule for Radiography (CCR).

Methods: Retrospective cross-sectional study of 3,753 consecutive adult patients presenting to an urban Level I emergency department who received C-spine CT scans were obtained over a 6-month period. The primary outcome of interest was prevalence of C-spine fracture. Secondary outcomes included fracture stability, appropriateness of imaging by NEXUS and CCR criteria, and estimated radiation dose exposure and costs associated with C-spine imaging studies.

Results: Of the 760 patients meeting inclusion criteria, 7 C-spine fractures were identified (0.92% ± 0.68%). All fractures were identified by NEXUS and CCR criteria with 100% sensitivity. Of all these imaging studies performed, only 69% met NEXUS indications for imaging (50% met CCR indications). C-spine CT scans in patients not meeting CDR indications were associated with costs of $15,500 to $22,000 by NEXUS ($14,600-$25,600 by CCR) in this single center during the 6-month study period.

Conclusion: For ground-level fall, C-spine CT is overused. The consistent application of CDR criteria would reduce annual nationwide imaging costs in the United States by $6.8 to $9.6 million based on NEXUS ($6.4-$15.6 million based on CCR) and would reduce population radiation dose exposure by 0.8 to 1.1 million mGy based on NEXUS (0.7-1.9 million mGy based on CCR) if applied across all Level I trauma centers. Greater use of evidence-based CDRs plays an important role in facilitating emergency department patient management and reducing systemwide radiation dose exposure and imaging expenditures.

Level Of Evidence: Diagnostic study, level III.

Download full-text PDF

Source
http://dx.doi.org/10.1097/TA.0000000000001073DOI Listing

Publication Analysis

Top Keywords

cervical spine
12
ground-level fall
12
radiation dose
12
dose exposure
12
imaging
8
c-spine
8
c-spine imaging
8
emergency department
8
c-spine scans
8
nexus ccr
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!