A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Safety and efficacy of everolimus-eluting bioresorbable vascular scaffolds versus durable polymer everolimus-eluting metallic stents assessed at 1-year follow-up: A systematic review and meta-analysis of studies. | LitMetric

Safety and efficacy of everolimus-eluting bioresorbable vascular scaffolds versus durable polymer everolimus-eluting metallic stents assessed at 1-year follow-up: A systematic review and meta-analysis of studies.

Int J Cardiol

Thoraxcentrum Twente, Medisch Spectrum Twente, Enschede, The Netherlands; Health Technology and Services Research, MIRA Institute for Biomedical Technology and Technical Medicine, University of Twente, Enschede, The Netherlands. Electronic address:

Published: October 2016

Background: The Absorb bioresorbable vascular scaffold (BVS) was developed to address long-term safety issues of metallic drug-eluting stents. However, it may be associated with an increased event risk during the first year.

Methods: A systematic literature search was performed (in MEDLINE/PubMed, Cochrane CENTRAL, EMBASE, and scientific meeting abstracts) to identify studies that compared BVS and cobalt-chromium durable polymer everolimus-eluting stents (EES). For randomized clinical trials and non-randomized propensity score matched studies that reported 1-year outcome data, fixed/random-effects models were used to generate pooled estimates of outcomes, presented as odds ratios (OR) with 95%-confidence intervals (CI).

Results: The 1-year follow-up data of 6 trials with 5588 patients were analyzed. A device-oriented composite endpoint (DOCE - cardiac death, target vessel myocardial infarction (MI), or target lesion revascularization (TLR)) was reached by 308 BVS or EES patients (195/3253 vs. 113/2315). Meta-analysis showed that patients who received BVS had an increased risk of MI (4.3% vs. 2.3%; OR:1.63, 95%-CI: 1.18-2.25, p<0.01) and definite-or-probable scaffold thrombosis (1.3% vs. 0.6%; OR:2.10, 95%-CI: 1.13-3.87, p=0.02). However, there was no significant between-group difference in risk of DOCE (6.0% vs. 4.9%; OR:1.19, 95%-CI: 0.94-1.52, p=0.16), cardiac death (0.8% vs. 0.7%; OR:1.14, 95%-CI: 0.54-2.39, p=0.73), or TLR (2.5% vs. 2.5%; OR: 0.98, 95%-CI:0.69-1.40, p=0.92).

Conclusions: During the first year of follow-up, patients treated with BVS had a higher incidence of MI and scaffold thrombosis. The risk of DOCE was not significantly different. As BVS may pay off later, future robust data on long-term clinical outcome will be of paramount importance.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ijcard.2016.07.101DOI Listing

Publication Analysis

Top Keywords

bioresorbable vascular
8
durable polymer
8
polymer everolimus-eluting
8
1-year follow-up
8
safety efficacy
4
efficacy everolimus-eluting
4
everolimus-eluting bioresorbable
4
vascular scaffolds
4
scaffolds versus
4
versus durable
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!