Ultra performance liquid chromatography tandem mass spectrometry assay for determination of kukoamine B in human blood and urine.

J Chromatogr B Analyt Technol Biomed Life Sci

Clinical Pharmacology Research Center & Translational Medicine Centre, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100032, China. Electronic address:

Published: September 2016

In this paper, we report a sensitive and rapid ultra performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method which is capable of quantifying kukoamine B (KB) levels in human blood and urine. Following solid phase extraction and direct dilution process, the analyte and its internal standard (D5-KB) run on an Acquity UPLC(®) HSS T3 column (2.1×50mm i.d., 1.8μm) by using a gradient elution method (run time was 1.5min). The mass spectrometric analysis was performed by using an API-5500 mass spectrometer coupled with an electro-spray ionization source. The MRM transitions of m/z 531.3(+)→222.1(+) and 536.3(+)→222.1(+) were used to quantify KB and D5-KB respectively. This assay method has been fully validated in terms of selectivity, linearity, lower limit of quantification, precision, accuracy, stability, recovery and matrix effect. The concentration range of this method is 10.0-2000.0ngmL(-1) in blood and 0.5-500.0ngmL(-1) in urine. Linearity (R(2)) of calibration curves were 0.9964±0.0022 and 0.9935±0.0053 for blood and urine, respectively (regression equation: y=ax+b). The precision (RSD%) of quality control samples is less than 10.3% for blood and less than 10.5% for urine. The accuracy (RE%) is within -4.0-11.3% and -11.7-12.5% for blood and urine respectively. KB was stable after 4h in ice-water bath, 1 freeze/thaw cycles and 180days at -80°C for blood samples; and was stable after 3h at room temperature, 3 freeze/thaw cycles and 180days at -80°C for urine samples. Recoveries of KB were 4.7±0.9% in blood and 96.5±1.3% in urine, respectively. Additionally, the applicability of this method has been proved by analyzing clinical samples from pharmacokinetic study of KB in human.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jchromb.2016.07.025DOI Listing

Publication Analysis

Top Keywords

blood urine
16
ultra performance
8
performance liquid
8
liquid chromatography
8
chromatography tandem
8
tandem mass
8
mass spectrometry
8
blood
8
human blood
8
urine
8

Similar Publications

Inhalation of elemental mercury is a rare cause of ARDS, with limited published case reports to provide guidance regarding disease progression and management. Although extracorporeal membrane oxygenation (ECMO) has been used to treat toxin-induced lung injury, its application to initial treatment and long-term recovery for inhalation of mercury remains undescribed. We present a case of a 56-year-old man who works at a thermometer factory presenting with severe ARDS secondary to inhaled elemental mercury with confirmatory blood and urine mercury levels.

View Article and Find Full Text PDF

The sensitive, efficient, and simultaneous assay of creatinine and urea in different body fluid is crucial for the daily detection and treatment of chronic kidney disease. Here, we exploited a versatile composite surface enhanced Raman scattering (SERS) substrate of polydimethylsiloxane (PDMS)-flower-like ZIF-67@Ag nanoparticles (NPs) based on simple in-situ growth and ion sputtering strategies. The plasmonic Ag NPs assembled on the three-dimensional anisotropic ZIF-67 matrix, facilitating numerous resonant electromagnetic "hotspots".

View Article and Find Full Text PDF

Background: Creatinine is a small molecule disease biomarker that reflects kidney function, accurate and effective detection of creatinine will play an important role in the prevention and treatment of diseases. Currently, commonly used creatinine detection methods are limited by expensive instruments, complex sample preparation, many interference factors from biological samples, and environmental factors that can affect the accuracy of the measurement. Therefore, developing a fast, simple, inexpensive, sensitive analysis method that can eliminate background interference and provide multi-detection modes has strong attraction and value.

View Article and Find Full Text PDF

Metabolomic analysis suggests thiamine monophosphate as a potential marker for mesenchymal stem cell transplantation outcomes in patients with SLE.

Lupus Sci Med

March 2025

Department of Rheumatology and Immunology, Nanjing Drum Tower Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, Jiangsu, China

Objective: The objective of this research is to identify metabolic markers associated with successful treatment by evaluating the effect of mesenchymal stem cell transplantation (MSCT) on the metabolic profiles of patients with SLE.

Methods: Plasma samples were collected from 20 patients with SLE before and after MSCT. Principal component analysis (PCA) was used to distinguish pretreatment and post-treatment groups and pathway analysis for identifying involved metabolic pathways.

View Article and Find Full Text PDF

Congenital cytomegalovirus (cCMV) is the leading infectious cause of neonatal neurological impairment worldwide, but the viral factors enabling vertical spread across the placenta remain undetermined. The pentameric complex (PC), composed of the subunits gH/gL/UL128/UL130/UL131A, has been demonstrated to be important for entry into nonfibroblast cells in vitro. These findings link the PC to broad cell tropism and virus dissemination in vivo, denoting all subunits as potential targets for intervention strategies and vaccine development.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!