Spatiotemporal registration of multiple three-dimensional echocardiographic recordings for enhanced field of view imaging.

J Med Imaging (Bellingham)

KU Leuven , Department of Cardiovasular Sciences, Cardiovascular Imaging and Dynamics Lab, UZ Herestraat 49, Box 7003, Leuven 3000, Belgium.

Published: July 2016

The use of three-dimensional (3-D) echocardiography is limited by signal dropouts and narrow field of view. Data compounding is proposed as a solution to overcome these limitations by combining multiple 3-D recordings to form a wide field of view. The first step of the solution requires registration between the recordings both in the spatial and temporal dimension for dynamic organs such as the heart. Accurate registration between the individual echo recordings is crucial for the quality of compounded volumes. A temporal registration method based on a piecewise one-dimensional cubic B-spline in combination with multiscale iterative Farnebäck optic flow method for spatial registration was described. The temporal registration method was validated on in vivo data sets with annotated timing of mitral valve opening. The spatial registration method was validated using in vivo data and compared to registration with Procrustes analysis using manual contouring as a benchmark. The spatial accuracy was assessed in terms of mean of absolute distance and Hausdorff distance between the left ventricular contours. The results showed that the temporal registration accuracy is in the range of half the time resolution of the echo recordings and the achieved spatial accuracy of the proposed method is comparable to manual registration.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4944392PMC
http://dx.doi.org/10.1117/1.JMI.3.3.037001DOI Listing

Publication Analysis

Top Keywords

field view
12
temporal registration
12
registration method
12
registration
9
echo recordings
8
spatial registration
8
method validated
8
validated vivo
8
vivo data
8
spatial accuracy
8

Similar Publications

Adaptive optics scanning light ophthalmoscopy (AOSLO) enables high-resolution retinal imaging, eye tracking, and stimulus delivery in the living eye. AOSLO-mediated visual stimuli are created by temporally modulating the excitation light as it scans across the retina. As a result, each location within the field of view receives a brief flash of light during each scanner cycle (every 33-40 ms).

View Article and Find Full Text PDF

Panoramic Nailfold Flow Velocity Measurement Method Based on Enhanced Plasma Gap Information.

J Imaging Inform Med

January 2025

State Key Laboratory of Traditional Chinese Medicine Syndrome/Health Construction Center, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, 510120, China.

Nailfold microcirculation examination is crucial for the early differential diagnosis of diseases and indicating their severity. In particular, panoramic nailfold flow velocity measurements can provide direct quantitative indicators for the study of vascular diseases and technical support to assess vascular health. Previously, nailfold imaging equipment was limited by a small field of view.

View Article and Find Full Text PDF

Objectives: Radiotherapy manages pancreatic cancer in various settings; however, the proximity of gastrointestinal (GI) luminal organs-at-risk (OAR) poses challenges to conventional radiotherapy. Proton beam therapy (PBT) may reduce toxicities compared to photon therapy. This consensus statement summarizes PBT's safe and optimal delivery for pancreatic tumors.

View Article and Find Full Text PDF

Development and evaluation of an in-beam PET system for proton therapy monitoring.

Phys Med Biol

January 2025

The Department of Biomedical Engineering, Huazhong University of Science and Technology, Wuhan, Hubei 430074, Wuhan, Hubei, 430074, CHINA.

Objective: In-beam positron emission tomography (PET) has important development prospects in real-time monitoring of proton therapy. However, in the beam-on operation, the high bursts of radiation events pose challenges to the performance of the PET system.

Approach: In this study, we developed a dual-head in-beam PET system for proton therapy monitoring and evaluated its performance.

View Article and Find Full Text PDF

A medical predicament has led to extensive drug resistance in methicillin-resistant Staphylococcus aureus (MRSA), and the complexity of treatment has increased exponentially with the induction of osteomyelitis. In view of the severe situation and the potential of bacterial antivirulence strategies, this study focused on the key virulence factor caseinolytic protease (ClpP) of S. aureus to identify new strategies against MRSA-induced osteomyelitis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!