A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Monitoring the primo vascular system in lymphatic vessels by using window chambers. | LitMetric

Monitoring the primo vascular system in lymphatic vessels by using window chambers.

Biomed Opt Express

Nano Primo Research Center, Advanced Institute of Convergence Technology, Seoul National University, Suwon 443-270, South Korea.

Published: April 2016

This study aims to develop a window chamber system in the skin of rats and to monitor the primo vascular system (PVS) inside the lymphatic vessels along the superficial epigastric vessels. The PVS in lymphatic vessels has been observed through many experiments under in vivo conditions, but monitoring the in vivo PVS in situ inside lymphatic vessels for a long time is difficult. To overcome the obstacles, we adapted the window chamber system for monitoring the PVS and Alcian blue (AB) staining dye solution for the contrast agent. The lymphatic vessels in the skin on the lateral side of the body, connecting the inguinal lymph nodes to the axillary lymph nodes, were the targets for setting the window system. After AB had been injected into the inguinal lymph nodes with a glass capillary, the morphological changes of the stained PVS were monitored through the window system for up to twenty hours, and the changes in the AB intensity in the PVS were quantified by using image processing. The results and histological images are presented in this study.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4929637PMC
http://dx.doi.org/10.1364/BOE.7.001251DOI Listing

Publication Analysis

Top Keywords

lymphatic vessels
20
lymph nodes
12
primo vascular
8
vascular system
8
window chamber
8
chamber system
8
inside lymphatic
8
inguinal lymph
8
window system
8
system
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!