Optomechanical cavities have been studied for applications ranging from sensing to quantum information science. Here, we develop a platform for nanoscale cavity optomechanical circuits in which optomechanical cavities supporting co-localized 1550 nm photons and 2.4 GHz phonons are combined with photonic and phononic waveguides. Working in GaAs facilitates manipulation of the localized mechanical mode either with a radio frequency (RF) field through the piezo-electric effect, which produces acoustic waves that are routed and coupled to the optomechanical cavity by phononic crystal waveguides, or optically through the strong photoelastic effect. Along with mechanical state preparation and sensitive readout, we use this to demonstrate an acoustic wave interference effect, similar to atomic coherent population trapping, in which RF-driven coherent mechanical motion is cancelled by optically-driven motion. Manipulating cavity optomechanical systems with equal facility through both photonic and phononic channels enables new architectures for signal transduction between the optical, electrical, and mechanical domains.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4941791 | PMC |
http://dx.doi.org/10.1038/nphoton.2016.46 | DOI Listing |
Can Assoc Radiol J
January 2025
Department of Radiology, Dalhousie University, Halifax, NS, Canada.
Contrast media, including iodinated contrast media and gadolinium-based contrast agents, are commonly administered pharmaceuticals with excellent safety profiles. However, a minority of the population may experience a hypersensitivity reaction following intravenous administration. Hypersensitivity reactions can be immediate or delayed, and range from mild, such as urticaria, to severe, including anaphylaxis.
View Article and Find Full Text PDFSensors (Basel)
January 2025
Department of Electrical and Computer Systems Engineering, Monash University, Melbourne, VIC 3800, Australia.
Conventional endoscopy is limited in its ability to examine the small bowel and perform long-term monitoring due to the risk of infection and tissue perforation. Wireless Capsule Endoscopy (WCE) is a painless and non-invasive method of examining the body's internal organs using a small camera that is swallowed like a pill. The existing active locomotion technologies do not have a practical localization system to control the capsule's movement within the body.
View Article and Find Full Text PDFSensors (Basel)
January 2025
Applied Research Laboratory, The Pennsylvania State University, State College, PA 16801, USA.
The frequency diverse array (FDA) is an architecture capable of beamforming in both range and angle, improving upon the traditional phased array (PA) which can only achieve beamforming in angle. The FDA employing directional modulation (DM) for secure directional communications (SDC) can reduce bit error rates (BERs) in both range and angle, again improving upon the traditional PA which can only reduce BER in angle. In this paper, we document the challenges involved in the design and implementation of a two-element linear FDA employing fast-time binary phase-shift keying (BPSK) modulations.
View Article and Find Full Text PDFSensors (Basel)
December 2024
CMEMS-UMinho, University of Minho, 4800-058 Guimarães, Portugal.
In biomedical research, telemetry is used to take automated physiological measurements wirelessly from animals, as it reduces their stress and allows recordings for large data collection over long periods. The ability to transmit high-throughput data from an in-body device (e.g.
View Article and Find Full Text PDFSensors (Basel)
December 2024
School of Electrical and Computer Engineering, National Technical University of Athens, 15772 Athens, Greece.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!