Background: Cross-linked polyethylene (XLPE) acetabular liners used in cementless total hip arthroplasty (THA) have demonstrated better wear resistance at 10 years compared with conventional polyethylene (CPE) liners. No clinical studies have compared XPLE to CPE liners beyond 10 years.

Methods: We performed a 15-year retrospective cohort study on cementless THA performed in patients with developmental hip dysplasia to measure the differences in polyethylene wear rates and the presence of osteolysis. Twenty-four THAs with XLPE and 17 THAs with CPE were evaluated. The mean age of patients was 55.9 years (41-68) in the XLPE group and 54.4 years (40-67) in the CPE group. The mean follow-up period was 15.1 years (13.9-16.1) in the XLPE group and 15.2 years (14.5-16.0) in the CPE group.

Results: The XLPE group had a significantly lower wear rate at 5 and 10 years compared with the CPE group; however, no significant difference was found at 15 years (XLPE group, 0.040 mm/y; CPE group, 0.034 mm/y). In addition, the incidence of osteolysis did not differ significantly between the groups. However, the incidence of excessive wear between 10 and 15 years after surgery in the XLPE group was significantly higher than that in the CPE group.

Conclusion: XLPE demonstrated no advantage in the wear rate or the incidence of osteolysis at 15 years, despite having superior wear resistance up to 10 years. It is concerning that the incidence of excessive wear was higher in the XLPE group between 10 and 15 years, and this finding should alert the arthroplasty community to this possible problem with the more highly cross-linked polyethylene.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.arth.2016.06.008DOI Listing

Publication Analysis

Top Keywords

xlpe group
24
cpe group
12
years
11
xlpe
9
group
9
wear
8
conventional polyethylene
8
cementless total
8
retrospective cohort
8
cohort study
8

Similar Publications

Background: This study aimed to determine the revision outcome between a centrally fixed stemless anatomic design and other total anatomic shoulder replacements using data from a large national arthroplasty registry.

Methods: The study period was from December 2011 to December 2022 and included three cohorts; primary Affinis stemless anatomic (AFS), all other primary total stemless anatomic (sTSA) and primary total stemmed anatomic shoulder arthroplasty (aTSA). The endpoint was all-cause revision using cumulative percent revision (CPR).

View Article and Find Full Text PDF

Background: The increased availability of dual-mobility acetabular constructs (DMCs) provides surgeons with a newer option to increase the effective femoral head size in revision total hip arthroplasty (rTHA). We sought to evaluate risks of re-revision and prosthetic dislocation following rTHA involving a DMC compared with other articulations.

Methods: A cohort study was conducted using data from a U.

View Article and Find Full Text PDF

Background And Purpose: We aimed to evaluate polyethylene (PE) wear, cup migration, and clinical outcome over 10 years in total hip arthroplasties (THA) using different articulations.

Methods:  This is a secondary analysis of 150 patients randomized into 5 groups, using different articulations: Charnley/Charnley Ogee for steel and conventional polyethylene (CPE), or Spectron EF/Reflection with either CPE or highly cross linked polyethylene (XLPE) cups, paired with heads made of either cobalt-chromium (CoCr) or oxidized zirconium (OxZr). All cups were cemented.

View Article and Find Full Text PDF

The present Bayesian network meta-analysis compared different types of polyethylene liners in total hip arthroplasty (THA) in terms of wear penetration (mm/year) and rate of revision. The type of liners compared were the crosslinked ultra-high molecular weight polyethylene (CPE/UHMWPE), Vitamin E infused highly cross-linked polyethylene (HXLPE-VEPE), modified cross-linked polyethylene (MXLPE), highly cross-linked polyethylene (HXLPE), Cross-linked polyethylene (XLPE). This study was conducted according to the PRISMA extension statement for reporting systematic reviews incorporating network meta-analyses of healthcare interventions.

View Article and Find Full Text PDF

Innovative approaches for augmenting dielectric properties in cross-linked polyethylene (XLPE): A review.

Heliyon

August 2024

Advanced Lightning, Power and Energy Research (ALPER), Department of Electrical and Electronics Engineering, Faculty of Engineering, University Putra Malaysia, 43400, Serdang, Malaysia.

Throughout the history of power systems, power cables have been used to securely and efficiently distribute electrical energy to the destined locations. Cross-linked polyethylene (XLPE), a commonly used insulator in high-voltage cables, have several desirable properties, such as low dielectric loss, high dielectric constant, high thermal conductivity, enhanced thermal stability, and superior resistance against electrical stress. However, further improvements of XLPE's performance are needed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!