Ex Vivo Assessment of a Parabolic-Tip Inflow Cannula for Pediatric Continuous-Flow VADs.

ASAIO J

From the *Department of Bioengineering, University of Pittsburgh, Pittsburgh, Pennsylvania; †McGowan Institute for Regenerative Medicine, Pittsburgh, Pennsylvania; ‡Department of Surgery, University of Pittsburgh School of Medicine, Pittsburgh, Pennsylvania; and §Artificial Heart Program, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania.

Published: November 2017

To address the challenge of unloading the left ventricle during pediatric mechanical circulatory support using next-generation rotary blood pumps, a novel inflow cannula was developed. This unique inflow cannula for pediatric, continuous-flow, left ventricular assist devices (VADs) with a parabolic-shaped inlet entrance was evaluated alongside a bevel-tip and fenestrated-tip cannula via an ex vivo, isolated-heart experimental setup. Performance was characterized using two clinical scenarios of over-pumping and hypovolemia, created by varying pump speed and filling preload pressure, respectively, at ideal and off-axis cannula placement to assess ventricular unloading and positional sensitivity. Quantitative and qualitative assessments were performed on the resultant hemodynamics and intra-ventricular boroscopic images to classify conditions of nonsuction, partial, gradual or severe entrainment, and ventricular collapse. The parabolic-tip cannula was found to be significantly less sensitive to placement position (p < 0.001) than the bevel-tip cannula under all conditions, while not statistically different from the fenestrated cannula. Visual analysis of the parabolic-tip cannula showed complete resistance to entrainment, whereas the fenestrated-tip had partial entrainment in 90% and 87% of the over-pumping and hypovolemic studies, respectively. We conclude that future pediatric VAD designs may benefit from incorporating the parabolic-tip inflow cannula design to maximize unloading of the left ventricle in ideal and nonoptimal conditions.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5001891PMC
http://dx.doi.org/10.1097/MAT.0000000000000411DOI Listing

Publication Analysis

Top Keywords

inflow cannula
16
cannula
10
parabolic-tip inflow
8
cannula pediatric
8
pediatric continuous-flow
8
unloading left
8
left ventricle
8
parabolic-tip cannula
8
vivo assessment
4
parabolic-tip
4

Similar Publications

"Caution with choroidals" - choose the right one at right time.

Indian J Ophthalmol

December 2024

Department of Oculoplasty, Disha Eye Hospitals Pvt Ltd, Kolkata, West Bengal, India.

Article Synopsis
  • Choroidal detachment (CD) during retinal detachment surgery can negatively affect surgical results and vision, necessitating specific management techniques.
  • Cannula-guided choroidal drainage is essential for mitigating pre-existing CDs, especially in complex cases with hemorrhagic detachment.
  • Intraoperative sudden CD can be caused by issues like hypotony or air entry from cannula slippage, which may lead to serious complications like Venous Air Embolism (VAE); prompt action to stop air infusion is critical to prevent life-threatening outcomes.
View Article and Find Full Text PDF

Objective: A less-invasive left atrial assist device (LAADx) is a novel and implantable, extracardiac blood pump concept, intended for the treatment of diastolic heart failure, represented by heart failure with preserved ejection fraction.

Methods: A mixed-flow pump was used as the working LAADx model. Its performance was evaluated at 3 speeds, using an in vitro pulsatile mock circulatory loop, with a pneumatic pump that can simulate diastolic heart failure conditions by adjusting the diastolic drive pressure.

View Article and Find Full Text PDF

The role of TandemHeart combined with ProtekDuo as right ventricular support device: A simulation approach.

Comput Methods Programs Biomed

December 2024

National Research Council, Institute of Clinical Physiology (IFC-CNR), 00185 Rome, Italy; Faculty of Medicine, Teaching University Geomedi, 0114 Tbilisi, Georgia. Electronic address:

Background And Objective: Right ventricular failure increases short-term mortality in the setting of acute myocardial infarction, cardiogenic shock, advanced left-sided heart failure and pulmonary arterial hypertension. Percutaneous and surgically implanted right ventricular assist devices (RVAD) have been investigated in different clinical settings. The use of the ProtekDuo™ is currently a promising approach due to its features such as groin-free approach leading to early mobilisation, easy percutaneous deployment, compatibility with different pumps and oxygenators, and adaptability to different configurations.

View Article and Find Full Text PDF
Article Synopsis
  • Left ventricular assist devices (LVADs) are commonly used to treat advanced heart failure, improving survival but leading to high rates of arrhythmias (20-50%) within a year after implantation.
  • Arrhythmias in these patients increase the risk of complications, such as additional shocks from implantable defibrillators and potential worsening of right ventricular failure, highlighting the need for tailored management strategies.
  • Effective treatment for these arrhythmias may involve specialized approaches like catheter ablation, though unique challenges exist in accessing arrhythmogenic areas after LVAD surgery, making pre-implantation procedures potentially beneficial.
View Article and Find Full Text PDF

Introduction: The Protek Duo (PtD) dual lumen, single cannula was developed as a percutaneous system for temporary mechanical support, inserted through the internal jugular vein (IJ) for both atrial inflow and pulmonary artery outflow. Outcomes of PtD compared to alternative Peripheral Right Ventricular Assist Device (pRVAD) methods are limited.

Methods: A retrospective analysis was conducted of pRVAD recipients from January 2017 - February 2022 ( = 111).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!